When the Skylight Flex switch is made up, by default ECFM, it is in the start state, but operationally in disable state, that is, it does not generate, receive or reply to any of the CFM PDUs once ECFM gets enabled. ECFM is enabled on all the interfaces that are up.
For Ethernet CFM entities (MEP and MIP) to function, ECFM must be enabled on each interface, where the CFM entities are configured, and all the ECFM entities must be configured (MD, MA, MEP, and MIP).
CLI Configurations
To enable ECFM on an interface
Enter into the global configuration mode.
your product# configure terminalEnable CFM processing globally.
your product(config)# ethernet cfm enable
Note: On enabling the ECFM, if the MEP is configured as active, LoopBack (LBM) and LinkTrace (LTM) messages can be transmitted and received.Enter into the interface configuration mode.
your product(config)# interface gigabitethernet 0/1Enable CFM processing on an interface.
your product(config-if)# ethernet cfm enable
To disable ECFM on an interface
- Enter into the interface configuration mode and disable CFM processing on an interface.
your product(config-if)# no ethernet cfm enable
SNMP Configurations
Enable ECFM at interface 1. [Index: Interface Number = 1]
% snmp 0 set {{fsMIEcfmPortModuleStatus.1 enabled }}Disable ECFM at interface 1. [Index: Interface Number = 1].
% snmp0 set {{fsMIEcfmPortModuleStatus.1 disabled }}