Enabling Ethernet Y.1731

Prev Next

By default, Y.1731 compliant features are in the disabled state. That is, it does not generate, receive or reply to any of the Y.1731 compliant CFM PDU(s).

ECFM must be enabled for Y.1731 to start functioning.

Y.1731 should be enabled for Y.1731 compliant features such as AIS, LCK, and so on, to start functioning.

CLI Configurations

To globally enable Y.1731

  1. Enter into the global configuration mode
    your product# configure terminal

  2. Enable CFM processing globally
    your product(config)# ethernet cfm enable

  3. Enable Y.1731 processing globally
    your product(config)# ethernet cfm y1731 enable

  4. Return to the privileged EXEC mode.
    your product(config)# exit

To globally disable Y.1731

  1. Enter into the global configuration mode and disable Y.1731 processing globally.
    your product(config)# no ethernet cfm y1731 enable

SNMP Configurations

  1. Enable Y.1731 processing globally [Index: ContextID = 0].
    % snmp0 set {{fsMIEcfmModuleStatus.0 enabled }}
    % snmp0 set {{fsMIY1731OperStatus.0 enabled }}
  2. Disable Y.1731 processing globally [Index: ContextID = 0].
    % snmp0 set {{fsMIY1731OperStatus.0 disabled }}