To view a summary of the statistics of each OAM instance
-
Access the page OAM â–¶Statistics.
-
For detailed OAM statistics, click the OAM instance Name in the list.
For more information on specific parameters, refer to the following tables.
OAM Statistics (OAM â–¶Statistics)
| Parameter | Description |
|---|---|
| Name | The name given to the OAM instance. |
| Rcv OAMPDU | The number of OAMPDUs received by this instance, all types combined: info, var request, var response, loopback etc. |
| Txm OAMPDU | The number of OAMPDUs transmitted by this instance, all types combined: info, var request, var response, loopback etc. |
| Rcv Info OAMPDUs | The number of Info OAMPDUs received by this instance. |
| Txm Info OAMPDUs | The number of Info OAMPDUs transmitted by this instance. |
Receive
| Parameter | Description |
|---|---|
| Unsupported Codes | A count of OAMPDUs received that contain an OAM code that is not supported by the device. This counter is incremented upon reception of a valid frame with the following:
|
| Information | A count of OAMPDUs received that contain the OAM Information code. This counter is incremented upon reception of a valid frame with the following:
|
| Loopback Control | A count of OAMPDUs received that contain the Loopback Control code. This counter is incremented upon reception of a valid frame with the following: Generalized and non-resettable, this counter has a maximum increment rate for slow protocol frames: no more than 10 frames are transmitted in any one-second period. |
| Variable Request | A count of OAMPDUs received that contain the Variable Request code. This counter is incremented upon reception of a valid frame with the following: Generalized and non-resettable, this counter has a maximum increment rate for slow protocol frames: no more than 10 frames are transmitted in any one-second period. |
| Variable Response | A count of OAMPDUs received that contain the Variable Response code. This counter is incremented upon reception of a valid frame with the following: Generalized and non-resettable, this counter has a maximum increment rate for slow protocol frames: no more than 10 frames are transmitted in any one-second period. |
| Organization Specific | A count of OAMPDUs received that contain the Organization Specific code. This counter is incremented upon reception of a valid frame, with: Generalized and non-resettable, this counter has a maximum increment rate for slow protocol frames: no more than 10 frames are transmitted in any one-second period. |
Transmit
| Parameter | Description |
|---|---|
| Unsupported Codes | A count of transmitted OAMPDUs that have unsupported codes. This counter is incremented when a request service primitive is generated within the OAM sublayer with an OAM code for afunction that is not supported by the device. Generalized and non-resettable, this counter has a maximum increment rate for slow protocol frames: no more than 10 frames are transmitted in any one-second period. |
| Information | A count of transmitted OAMPDUs containing the OAM Information code. This counter is incremented when a request service primitive is generated within the OAM sublayer with an OAMPDU code indicating an Information OAMPDU. Generalized and non-resettable, this counter has a maximum increment rate for slow protocol frames: no more than 10 frames are transmitted in any one-second period. |
| Unique Event | A count of transmitted OAMPDUs containing the OAM Unique Event code. This counter is incremented when a request service primitive is generated within the OAM sublayer.
|
| Duplicate Event | A count of transmitted OAMPDUs containing the OAM Duplicate Event code. This counter is incremented when a request service primitive is generated within the OAM sublayer.
|
| Loopback Control | A count of transmitted OAMPDUs containing the Loopback Control code. This counter is incremented when a request service primitive is generated within the OAM sublayer with an OAM code indicating a Loopback Control OAMPDU. Generalized and non-resettable, this counter has a maximum increment rate for slow protocol frames: no more than 10 frames are transmitted in any one-second period. |
| Variable Request | A count of transmitted OAMPDUs containing the Variable Request code. This counter is incremented when a request service primitive is generated within the OAM sublayer with an OAM code indicating a Variable Request OAMPDU. Generalized and non-resettable, this counter has a maximum increment rate for slow protocol frames: no more than 10 frames are transmitted in any one-second period. |
| Variable Response | A count of transmitted OAMPDUs containing the Variable Response code. This counter is incremented when a request service primitive is generated within the OAM sublayer with an OAM code indicating a Variable Request OAMPDU. Generalized and non-resettable, this counter has a maximum increment rate for slow protocol frames: no more than 10 frames are transmitted in any one-second period. |
| Organization Specific | A count of transmitted OAMPDUs containing the Organization Specific code. This counter is incremented when a request service primitive is generated within the OAM sublayer with an OAM code indicating a Variable Request OAMPDU. Generalized and non-resettable, this counter has a maximum increment rate for slow protocol frames: no more than 10 frames are transmitted in any one-second period. |
© 2025 Cisco and/or its affiliates. All rights reserved.