System Health

Prev Next

System Health CSV File Description (and KPI if applicable)

Col. No.

Field Name

Field Description

Units/Values

Examples

1

SFP Data Type

Data type

This value is always SFP. SFPs are Cisco devices.

SFP

2

Date

Date and time at the beginning of the collection period

YYYY-MM-DD HH:MM:SS±hh:mm

YYYY-MM-DD: Date

HH:MM:SS: Local Time

hh:mm: UTC Offset + DST

2014-07-11 20:00:57+04:08

3

System

System name, as defined by DNS name in the unit

By default, this value is the serial number.

C037-0242

4

Firmware Version

Current firmware version

PFID_A.B.C.D_build

PFID: Product Family ID (AEN, AMO-10000- LT, etc.)

A.B.C.D: Release number

build: build number

VFS10G_1.1_34283

5

Hardware Version

Hardware assembly version of unit

500-018-04

6

Serial Number

Serial number of unit. Unique identifier assigned by the manufacturer.

Format: ANNN-NNNN

C037-0242

7

Model

For more information, please refer to Product Model Information.

8

Interval

Duration of the configured reference period

Possible values: 1 to 60 minutes.

Default is 15 minutes.

1

9

Duration

Actual duration of the period during which data was collected

seconds

38

60

10

Period

Index number assigned to a collection period

2065

2070

11

CPU Usage Realtime (%) (KPI)

Average CPU usage determined in real time

%

4

2

12

CPU Usage Lifetime (%) (KPI)

Average CPU usage since the system was started for the first time

%

4.26

4.21

13

Memory Usage (MB) (KPI)

Memory usage value obtained from the operating system

MiB

77

14

Memory Free (MB) (KPI)

Free memory value obtained from the operating system

MiB

45

15

Memory Buffer (MB) (KPI)

Memory buffer value obtained from the operating system

MiB

0

16

Memory Cache (MB) (KPI)

Memory cache value obtained from the operating system

MiB

0

17

Memory Shared (MB) (KPI)

Shared memory value obtained from the operating system

MiB

0

18

Memory Swap (MB) (KPI)

Swap memory value obtained from the operating system

MiB

0

19

Temperature Sensor #1 (KPI)

Actual temperature detected in the device.

Supported for Assurance Sensors: GX and LT.

Not supported for Assurance Sensors: GT.

Degrees Celsius

40

20

Temperature Sensor #2 (KPI)

Actual temperature detected in the device.

Supported for Assurance Sensors: GX and LT.

Not supported for Assurance Sensors: GT.

Degrees Celsius

37

21

Temperature Sensor FPGA (KPI)

Actual temperature detected near the FPGA.

Supported for Assurance Sensors: GX and LT.

Not supported for Assurance Sensors: GT.

Degrees Celsius

0

38

22

History Partition Disk Usage (%) (KPI)

Percentage of the system disk used to store performance data

%

0.03

23

Configuration Partition Disk Usage (%) (KPI)

Percentage of the system disk used to store system configuration

%

9.12

24

Fan #1 Speed (KPI)

Actual speed of fan

Supported for Assurance Sensors: GX and LT.

Not supported for Assurance Sensors: GT.

Unit: RPM

10679

25

Fan #2 Speed (KPI)

Actual speed of fan

Supported for Assurance Sensors: GX and LT.

Not supported for Assurance Sensors: GT.

Unit: RPM

10522

26

Uptime (KPI)

Time elapsed since the last boot of the system

seconds

2110

© 2025 Cisco and/or its affiliates. All rights reserved.

For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and trademarks