SOAM PL

Prev Next

SOAM PL CSV File Description (and KPI if applicable)

Col. No.

Field Name

Field Description

Units/Values

Examples

1

CFMPL Data Type

Data type

This value is always CFMPL.

CFMPL

2

Date

Date and time at the beginning of the period

YYYY-MM-DD HH:MM:SS±hh:mm

YYYY-MM-DD: Date

HH:MM:SS: Local Time

hh:mm: UTC Offset + DST

2014-09-15 10:44:00-04:00

3

System

System name, as defined by DNS name in the unit. By default, this value is the serial number.

G274-0010

4

Firmware Version

Current firmware version

PFID_A.B.C.D_build

PFID: Product Family ID (AEN, AMO-10000- LT, etc.)

A.B.C.D: Release number

build: build number

AMT_6.4.1.2_35204

5

Hardware Version

Hardware assembly version of unit

500-032-01

6

Serial Number

Serial number of unit. Unique identifier assigned by the manufacturer.

Format: ANNN-NNNN

G274-0010

7

Index

Unique index number (auto-generated)

1

8

Status

State of this instance

enabled, disabled

enabled

9

MD index

Maintenance Domain index. Unique index assigned to the MD, with which the MEP is associated.

1-8

5

10

MD name

Maintenance Domain name: Unique pseudonym (not defined in standard) assigned to MD.

Y.1731 level 0 to Y.1731 level 7

Y.1731 level 4

11

MD level

Maintenance Domain level

0 to 7

4

12

MA/MEG index

The unique index of the Maintenance Association (MA) / Maintenance Entity Group (MEG) with which the MP is associated.

1

13

MA/MEG name

Name of the MA/MEG

Up to 31 alphanumeric characters

MEG1

14

MA/MEG level

Maintenance level of the MA/MEG

0 to 7

4

15

MA/MEG CCM interval

Configured interval between Continuity Check Messages (CCM)

ms

1000

16

MA/MEG VLAN type

VLAN type (TPID) associated with the MA/MEG

None, C-VLAN, S-VLAN, T-VLAN

C-VLAN

17

MA/MEG VLAN ID list

List of VLANs associated with this MA/MEG

100

18

MA/MEG MEPID list

List of all MEPs associated with this MA/MEG

1,2

19

MEP ID

Maintenance association End Point (MEP) Identifier for this MA/MEG

1

20

MEP index

Index assigned to the MEP

1

21

Remote MEP ID

Index assigned to the remote MEP

2

22

MAC Address

MAC address of the port used by this MEP

00:15:AD:11:A5:FC

23

Remote MAC Address

MAC address of the port used by the remote MEP

00:15:AD:08:D8:AE

24

Port

Name of the port used by this MEP

Default port names are platform-dependent.

May also be user-defined.

PORT-4

25

Direction

The direction in which the MEP faces on the Bridge port

Down, Up

Down

26

Active

Administrative state of the MEP

enabled, disabled

enabled

27

Primary VID

The primary VLAN ID of the MEP (one of the VLAN IDs assigned to the MA/MEG)

0

28

CCI enable

Whether the MEP generates CCM messages or not

enabled, disabled

enabled

29

CCM sequence number

Indicates whether CCM sequence numbering is enabled or not

enabled, disabled

enabled

30

CCM and LTM priority

Priority level assigned to CCM, LTM and CCF frames transmitted by the MEP

0 to 7

7

31

Interval

Filing interval

1 to 60 minutes

1

32

Samples

Number of samples taken during this period

60

33

Period

Period number (sequential)

1220

34

Priority

Priority of VLAN (if present)

0 to 7

7

35

Alert

Indicates presence of Packet Loss alert (alarm)

FALSE, TRUE

FALSE

36

Valid

Indicates validity of Packet Loss measurements

TRUE, FALSE

FALSE if the PL instance is disabled.

Otherwise, TRUE

TRUE

37

Packets (KPI)

Number of packets (CCM messages) expected during the reference period

samples

60

38

Packets lost (KPI)

Number of samples lost during the period.

samples

2

39

Packet loss ratio (KPI)

Loss ratio = Lost/Total Expected (expressed as a percentage)

%

3.333333

40

Gaps (KPI)

Number of gaps during the period

gaps

1

41

Largest gap (KPI)

Largest gap during the period

samples

2

42

Model

For more information, please refer to Product Model Information.

43

Remote Device Name

User-assigned name

Note: Available as of firmware version 7.8.3

Device_A

44

Remote Device Serial

Manufacturer-assigned serial number

Note: Available as of firmware version 7.8.3

P009-0027

45

Remote Device Product

Manufacturer-assigned product model

Note: Available as of firmware version 7.8.3

ANN-1000-T

46

Remote Device Version

Version of device firmware

Note: Available as of firmware version 7.8.3

2.4_11061

47

Remote Device Active Feature

Feature load currently used on the remote device

Note: Available as of firmware version 7.8.3

Possible values:

TGEN: Traffic generation (used to perform SAT tests).

PMON: Performance monitoring (all other features, including service OAM, traffic management and loopbacks).

None: No load is detected.

PMON

48

Name

Packet loss name

Note: Available as of firmware version 7.8.3

PKT_LOSS_TEST1

PKT_LOSS_TEST3

© 2025 Cisco and/or its affiliates. All rights reserved.

For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and trademarks