Field Replacement of a Skylight sensor: control
  • 21 Jun 2024
  • 2 Minutes to read
  • Contributors
  • PDF

Field Replacement of a Skylight sensor: control

  • PDF

Article summary

Software Specifications

This appendix explains how to replace a broken endpoint (hardware) in a running supervision case. All endpoints are assigned a unique node identifier (NodeId). The Node ID is initially set to the same value as the unit identifier (UnitId) during the boot up phase of the endpoint. The Node ID can later be configured in the endpoint CLI.

The new endpoint, which will replace the old endpoint, must be configured with the old endpoint’s Node ID before it can be used in the supervision case. The following section explains the steps required to replace an endpoint.

Procedure Steps for Field Replacement

To replace a Skylight sensor: control with the same IP

  1. Log in to the mgr-command of the Skylight orchestrator via the app_mon to find the node ID of the failed Skylight sensor: control.

  2. From the Managed Elements tab in Skylight orchestrator, update the entry for the failed Skylight sensor: control to the IP address of the replacement instance.

  3. Establish connectivity.

  4. Restore the last configuration backup to the replacement Skylight sensor: control via the Devices ▶ Backup & Restore tab.

  5. Once the new Skylight sensor: control has started with the restored configuration, log into the CLI interface and update the node ID to match the node ID of the instance being replaced.

  6. In the orchestrator GUI, stop and then restart all sessions associated with this Skylight sensor: control.

To replace a Skylight sensor: control with a different IP

  1. Log in to the mgr-command of the Skylight orchestrator via the app_mon to find the node ID of the failed Skylight sensor: control.

  2. From the Managed Elements tab in Skylight orchestrator, update the entry for the failed Skylight sensor: control to the IP address of the replacement instance.

  3. Establish connectivity.

  4. Restore the last configuration backup to the replacement Skylight sensor: control via the Devices ▶ Backup & Restore tab.


    Note: Skip step 5 if the failed device has enabled DHCP.

  5. Once the new Skylight sensor: control has started with the restored configuration, log into the CLI interface and update the node ID to match the node ID of the instance being replaced.


    Note: Skip step 6 if DHCP is enabled on old device and new device.

  6. From the Managed Elements tab in Skylight orchestrator, update the entry for the new Skylight sensor: control with the changed IP address.

  7. In the orchestrator GUI, stop and then restart all sessions associated with this Skylight sensor: control.

© 2024 Cisco and/or its affiliates. All rights reserved.
 
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks



Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.