Services that have been created locally on the unit can be included in a Y.1564 or RFC-2544 test by enabling an internal loopback on one of the unit’s UNI ports to redirect the test traffic through the traffic policies.

A test where an internal loopback is enabled on both UNI ports (i.e. near-end and far-end), thus enabling services to be tested from end to end as in illustration.

UNI-to-UNI (End-to-End) Testing

image-3N2MMFUA.png

The traffic in this end-to-end test moves seamlessly between the two units:

  • The test traffic is generated toward the local UNI port on Unit 1.
  • The internal loopback on Unit 1 redirects the traffic to the policies stage, then toward the NNI port.
  • The test traffic enters Unit 2 and goes through the policies before reaching the UNI port.
  • Another internal loopback is used on Unit 2's UNI port to loop the traffic and send it back to Unit 1.
  • In both units, the traffic goes to the policing stages for the ingress direction as well as for the egress direction.

The units can also be configured to perform UNI-to-NNI testing, as well as NNI-to-UNI testing, as shown in illustration.

UNI-to-NNI Testing

image-A8MI8YTC.png

NNI-to-UNI Testing

image-U1H6EH0N.png


Notes: The Internal Loopback functionality only supports Layer-2 and Layer-2 Accedian test frames in conjunction with two-way tests. Other types of test traffic, such as Layer-2 Generic, Layer-3, are not supported.
When using an internal loopback, the maximum throughput is limited to 50% of the line rate.

To enable an internal loopback, access the Port Configuration menu. For details, see "Setting Up Ports".

© 2024 Cisco and/or its affiliates. All rights reserved.
 
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks



Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.