Accedian is delighted to announce release 21.12.1 of Skylight sensor: agents.
What's New
21.12.1 addresses a specific issue with sensor actuate and next-hop gateway MAC address when run on Cisco docker environments. 21.12.1 is fully compatible with 21.12 Analytics for orchestration.
To use the next-hop gateway fix for Cisco the environment variable below needs to be set on the docker command line or in the docker-compose file
AGENT_STANDARD_TRANSMISSION=true
If not setting this variable, the 21.12.1 agent will behave exactly the same as 21.12 GA agent.
Release Components
Component | Version | Note |
---|---|---|
agent actuate | skylight-agent-actuate-amd64_21.12.1_817 |
Corrected Issues
ID | description | workaround |
---|---|---|
SA-775 | Wrong MAC address selected for next-hop gateway |
Known Issues
ID | description | workaround |
---|---|---|
SA-787 | ICMP echo IPv6 is not working | Use UDP echo IPv6 instead |
SA-306 | Payload size for IPv6 TWAMP can be set to larger values than the MTU | Do not use larger IPv6 payload size than 1452b |
SA-509 | TWAMP-CP: When control session is down, data is not accepted into analytics | Make sure the (3rd party) TWAMP responder is up |