- Print
- PDF
Skylight performance element: LT Release Notes 7.9.6
These release notes cover the requirements, new features, and changes for the Skylight Element: LT firmware version 7.9.5.1 Please read all notes prior to installing this firmware version. For more information, refer to: Skylight performance element LT User Material
Requirements
This firmware version applies to the following Skylight element: LT, resulting from changes in the TLS version, the following software versions are compatible with SkyLIGHT Director Version 1.3 (now Skylight orchestrator) and above:
- 7.1.1.1
- 7.3.0.3
- 7.4
- 7.5
- 7.6
- 7.7
- 7.8
- 7.8.1
- 7.8.2
- 7.8.2.1
- 7.8.3
- 7.9
- 7.9.1
- 7.9.2
- 7.9.3
- 7.9.4
- 7.9.5
- 7.9.5.1
- 7.9.6
Note: There is a patch available for earlier versions of Skylight orchestrator. Please contact Accedian support for further information.
Firmware Version 7.9.6_25448 (2023-08-18)
New Features and Enhancements
Top command added to tech support file
The “top -b -n 1” command added to the tech support file and report generation includes information for CPU and memory usage per process.
Addressed Issues
Password with “#” character causing error message in y1564 report transfer
When a Y.1564 transfer report is done via CLI, and the password or username of the destination has a special character “#”, the transfer fails with an error message.
This issue has been fixed.
Hostname does not accept “/”
If editing the hostname and using “/” the customer receives invalid parameter value error.
This issue has been fixed.
Hostname does not accept “.”
If editing the hostname and using “.” the customer receives invalid parameter value error.
This issue has been fixed.
Operational Considerations
Important Notes
- The Skylight element: LT firmware is delivered in a consolidated file prefixed by “ACC”, e.g. ACC_7.X_YYYY.afl. This file contains the firmware for the GT, GX , LX and LT Performance Element products. It cannot be used with any other product.
- IMPORTANT: Prior to upgrading the firmware on a unit where the History Buckets feature is enabled, certain precautions may need to be taken to prevent a loss of history data during the upgrade.
- After upgrading to 7.9.1 or 7.9.2, the SCP is no longer able to send files, reporting the following error: Code = 3: URL using bad/illegal format or missing URL. This is due to a syntax change and customer needs to edit the URL after upgrading to 7.9.2 or 7.9.3.
The URI generic syntax (in RFC 3986) consists of a hierarchical sequence of five components: URI = SCHEME ':' ['//' AUTHORITY] PATH ["?" QUERY] ["#" FRAGMENT]. In this, AUTHORITY = [USER_INFO "@"] HOST [":" PORT]. The AUTHORITY part and the PATH part are isolated by the slash ('/') character if the AUTHORITY exists.
© 2024 Cisco and/or its affiliates. All rights reserved.
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms
For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks