Setting Up SyncE
  • 23 Jan 2024
  • 4 Minutes to read
  • Contributors
  • Dark
    Light
  • PDF

Setting Up SyncE

  • Dark
    Light
  • PDF

Article Summary

If your equipment has this optional hardware feature, you can use the synchronous Ethernet (SyncE) feature to synchronize the unit and all its outputs over Ethernet networks. SyncE takes the clock signal from the selected clock reference port and transmits it to all other ports. You also have the option to define a Secondary Clock Source on another physical port.


Note: When advertising a new clock class in SyncE and PTP a trap will now be generated and provide the new clock class, see article on MIB for more information. Management Information Base

To set up SyncE

  1. Access the page Port ▶SyncE.

  2. Select Enable SyncE.

  3. Complete the required fields, then click Apply.

For more information on specific parameters, refer to the following tables.

SyncE/ESMC Parameters (Port ▶SyncE)

ParameterDescription
Enable SyncEEnables or disables the synchronous Ethernet feature.
  • When disabled, all ports on the system operate as clock master. When enabled, the clock reference port(s) operate as clock slave (s) and all the other ports on the system operate as masters, transmitting clock signal from clock reference port.
  • When enabled, clock status information is also displayed.

Options

ParameterDescription
Primary Clock SourceThe port from which the Primary Reference Clock is recovered.
Secondary Clock SourceThe port from which the Secondary Reference Clock is recovered. This parameter is optional and may be set to none if only a single reference clock is preferred.
RevertiveEnables or disables the revertive clock selection feature.
  • When enabled, the clock selector is allowed to switch back to a higher-priority clock source that previously failed when it becomes available again
  • When disabled, the clock selector is allowed to revert to a lower priority clock source, but only if the currently selected source becomes unavailable. In this mode, the selector cannot revert to a clock that previously failed.
Wait-to-Restore Delay (sec)The system will wait for this many seconds before reverting to a clock available after a failure.

Note: This feature applies when ESMC QL Mode is enabled.

Manual Clock SourceThis sets the clock selector to use a specific clock source, regardless of priority.

Note: The system will not switch to an invalid clock and it will not switch to a clock of inferior quality (if ESMC QL mode is enabled). If none is specified, the clock source is selected automatically.

ESMC QL ModeEnable or disable the ESMC QL mode. ESMC QL messages containing clock quality information can be sent and received only if this is enabled. If enabled, clock quality information can then be used to automatically select the best clock reference available.
ESMC Forward extended TLVESMC messages may contain type-length-values (TLV) other than the mandatory QL TLV. These are referred to as extended TLVs. Their content is not used in the system. When enabled, extended TLVs will be forwarded from incoming SyncE ports to all outgoing SyncE ports; if not enabled, they are stripped out.

Note: This feature applies when ESMC QL Mode is enabled.

ESMC Port ExclusionThe ESMC Port Exclusion box lists all available ports to choose from. When selected, ports will not transmit or receive ESMC QL messages.

Note: An error message will pop up if the selected port is the same as the Primary or Secondary.

Note: “Cltr + Clicking” on desired Port(s) to deselect.

Note: This option is available for LX-SyncE only.

Status

ParameterDescription
Clock SelectorThe clock source that is currently in use by the SyncE hardware.

Possible values are:

  • Primary: The primary reference clock is in use.
  • Secondary: The secondary reference clock is in use.
  • Local: The local oscillator is in use. This should only happen when SyncE is disabled.
Primary Clock StatusThe current status of the primary reference clock.
Secondary Clock StatusThe current status of the secondary reference clock.
Clock Selection Change CountThe number of times the clock reference was changed.
Current QL StateThe current QL status.

Note: This feature is not available if ESMC QL Mode is disabled.

Previous QL StateThe previous QL status with the time elapsed in seconds (with millisecond resolution) since the change occurred.

Note: This feature is not available if ESMC QL Mode is disabled.

Previous Clock SelectorThe previous clock selector with the time elapsed in seconds (with millisecond resolution) since the change occurred.

Port Statistics Summary (only available if ESMC QL mode is enabled)

ParameterDescription
StatusThe following colors indicate SyncE port status:
  • Green: The port is up and running.
  • Blue: Indicates the selected port for ESMC Port Exclusion and that the link is still up, but can not transmit or receive the ESMC QL messages.
  • Red: The port is enabled but the physical link is down and no signal is detected.
  • Yellow: The port is not totally functional.
  • Gray: The port is disabled.
Port NameThe name that identifies the port. A link can be clicked to access detailed SyncE/ESMC port statistics.
Tx QLLast transmitted clock QL on the port.

Note: This Count will not increase if the statistic is cleared (displayed as 0).

Note: Tx QL represents the last TX ESMC package, and should be kept as it is.

Rx QLLast received clock QL on the port. .

Note: This Count will not increase if the statistic is cleared (displayed as 0).

Note: Rx QL represents the last RX ESMC package, and should be kept as it is.

QL StateCurrent QL receive status used for selection process if the port is a reference clock.

Note: The QL-FAILED state indicates that the port is in a failed condition.

State DurationTime elapsed in seconds since QL state was last changed.

© 2024 Accedian Networks Inc. All rights reserved. Accedian®, Accedian Networks®,  the Accedian logo™, Skylight™, Skylight Interceptor™ and per-packet intel™, are trademarks or registered trademarks of Accedian Networks Inc. To view a list of Accedian trademarks visit: http://accedian.com/legal/trademarks/. 


Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.