Results (1437)
Drill Down on an Individual Alert
Latest Documentation
English
Overview In an alert-based analysis, you can drill down on an alert to see why violations were raised and which metrics are associated with the alert. To drill down on an alert, you must: Apply an alert policy as
Setting Up Virtual Connection Access (VCAs) VLAN
Latest Documentation
English
page Virtual Connection ▶ VCA VLAN ▶ Configuration . On the top right, from the Remote Device drop-down list, select the device you require. Click the VCA-VLAN name to display the detailed information for the VCA-VLAN. Click Add
Using Y.1564 for Service Activation Testing
Latest Documentation
English
Near-end UDP port used to generate PDUs. Applies to Layer 3 traffic only. Destination port Far-end UDP port number associated with the IP address of the unit that will receive, process, and display traffic statistics and report. Applies
REST API Requirements
Latest Documentation
English
To use the API and view the API documentation, you need the following: Legacy Orchestrator appliance If a Legacy Orchestrator appliance is available for development purposes, you will need its IP address and a user account. Default administrator account: admin
Managing the Loop Detection Diagnostic Tool
Latest Documentation
English
Use this page to create a manually controlled, customized loop detection beacon, then view its results. Note: The loop detection diagnostic tool does not require an interface to be created in order to send a tunnel-level beacon. To configure
Skylight sensor agents 21.12 Release Notes
Latest Documentation
English
Overview Accedian is pleased to announce release 21.12 of Skylight sensor: agents. What's New 21.12 is the second GA release of the Skylight sensor: agent and contains a number of new features and functions compared to the
Using the RFC-2544 Test Suite
Latest Documentation
English
be successful, the network being tested must not lose any frames after a burst. A two-second pause is inserted after each burst. Ensure to enter all required parameters in the  Throughput settings  section as some of these parameters
Setting Up Virtual Connection Endpoints (VCEs)
Latest Documentation
English
To view a summary of existing VCEs Access Virtual Connection ▶VCE ▶Configuration . A list of all existing VCEs and their current status is displayed. Note: A type Tunnel VCE will create an implicit VCA which can be included within another
sync-group
Latest Documentation
English
sync-group disable sync-group disable - Disable configuration and Sync Groups on the Sensor Control Description: Disable configuration and clear all active Sync Groups. Syntax: sync-group disable sync-group enable sync-group enable - Configure and enable Sync Group on
cfm
Latest Documentation
English
{fault-propagation } | {fp-port } | {interface-status-tlv } }+ lowest-alarm-pri-choice = {all | macRemErrXconAis | remErrXconAis | errXconAis | xconAis | ais | none>} Parameters: Parameter Description meg-idx MEG index. Identifies the MEG that MEP belongs to. Cannot be used in conjunction with meg
Skylight Analytics 20.03 Release Notes
Latest Documentation
English
Next-gen Analytics arrives! Capture data, alerts, reports, evolved dashboards, macro analysis, faster queries, better UX - it's all here! Whew, this is a big one! We put massive investments into our architecture over the last year, which we've
Querying Session PM data via API
Latest Documentation
English
The user interface of Provider Connectivity Assurance uses data retrieved via our OpenAPIs. API Calls to Provider Connectivity Assurance If you aren't familiar with REST APIs, we recommend going to our intro page here to review that first . To
Accedian YANG Notifications Examples and Common Error Codes
Latest Documentation
English
409 UX Message Suggestion Skylight Gateway : Service serviceid_test not found GET a session-id that Doesn't Exist Error Message { "errors": { "error": [ { "error-path": "/Accedian-session:sessions/session[session-id='test-session']", "error-type": "application", "error-tag": "data
Managing Alarms
Latest Documentation
English
FPGA high-temperature alarm ERP module In this section, xxxx = ERP instance index. Parameter Default Description 9.xxxx.01 ERP protocol version mismatch 9.xxxx.02 ERP force switch 9.xxxx.03 ERP manual switch 9.xxxx.04 ERP signal
Configuring the Unit
Latest Documentation
English
gps
Latest Documentation
English
gps edit gps edit - Edit GPS settings Description: Configure the GPS receiver settings. Syntax: gps edit { state { enable | disable } } Parameters: Parameter Description state Enable or disable GPS synchronization. gps show configuration gps show configuration - Show GPS configuration Description: Display the
nfv-tunnel
Latest Documentation
English
nfv-tunnel show status nfv-tunnel show status - Display NFV tunnel status and quality. Description: Show the tunnel status and the quality. Syntax: nfv-tunnel show status [ ] = Parameters: Parameter Description device name Name of the remote device. © 2026 Cisco
Commissioning
Latest Documentation
English
Using Service Availability
Latest Documentation
English
statistics) HLI This counter increments for every high-loss interval. This counter is reset to zero when one of the following conditions occur: Device reboot Counter reset (you clear the statistics) Validity The SA counters validity may have one of
Setting Up an OAM Instance
Latest Documentation
English
Before using Ethernet OAM functions or enabling a loopback, you must create an OAM instance upon which the loopback is created. Note: You do not have to enable L2PT rules in order to forward untagged OAM frames directly to the