Upgrading Assurance Sensor F100 / F25
  • 27 Aug 2024
  • 2 Minutes to read
  • Contributors
  • PDF

Upgrading Assurance Sensor F100 / F25

  • PDF

Article summary

Overview

The following procedure is recommended to upgrade a Provider Connectivity Assurance Sensor F100 or F25 unit using the AFL file and the CLI. The Assurance Sensor F100 and F25 platforms have enough space on the storage to save two copies of the entire software.

Product NameSoftware VersionBuild NumberSoftware Files
Assurance Sensor F10024.08 GA2800

AMO-100G-NG_24.08_2800.afl.startup

AMO-100G-NG_24.08_2800.afl

Accedian_MIB_2800

Accedian_YANG_2800

Assurance Sensor F2524.08 GA2800

AMO-25G-NG_24.08_2800.afl.startup

AMO-25G-NG_24.08_2800.afl

Accedian_MIB_2800

Accedian_YANG_2800


Note: Assurance Sensor F100 software file is used in the following example.

Using AFL File for Client

Downloading AFL Firmware

To download firmware using TFTP

  1. From the file server accessible to clients, download the file:
AMO-100G-NG_24.08_2800.afl
  1. Copy the file to the TFTP server; example: 10.247.0.70
scp AMO-100G-NG_24.08_2800.afl <user>@10.247.0.70:/home/<user>/TFTP_File_Server/tftpboot

OR

To download firmware using SFTP

  1. From the file server accessible to clients, download the file:
AMO-100G-NG_24.08_2800.afl
  1. Copy the file to the SFTP server, example: 192.168.1.109
scp AMO-100G-NG_24.08_2800.afl <user>:<Pass>@192.168.1.109:/home/<user>/SFTP_File_Server/sftpboot

Installing AFL Firmware on Assurance Sensor F100

This install procedure requires a 2-step process, retrieving the file (a), followed by activation (b). These steps can be accomplished independently.


Note: Although optional, saving the running-config to the startup-config is required if intending to bring back the running-config after activating the new firmware.

To install firmware using TFTP

  1. Do the following from the unit:
    a) Retrieve the official AMO-100G-NG_24.08_2800.afl file from the TFTP server by typing following commands in the CLI:

ssh root@x.x.x.x <--- IP address of your unit.

archive download-sw /overwrite tftp://10.247.0.4/AMO-100G-NG_24.08_2800.afl

b) Activate the firmware:

configure terminal
firmware activate; exit; exit
  1. Wait approximately two minutes as the unit will reboot.

OR

To install firmware using SFTP

  1. Do the following from the unit:
    a) Retrieve the official AMO-100G-NG_24.08_2800.afl file from the SFTP server by typing following commands in the CLI:

ssh root@x.x.x.x <--- IP address of your unit.

archive download-sw /overwrite sftp://sftp_user:sftp_user@192.168.1.109/AMO-100G-NG_24.08_2800.afl

b) Activate the firmware:

configure terminal
firmware activate; exit; exit
  1. Wait approximately two minutes as the unit will reboot.

Verifying the Active Firmware Version

Validate the active firmware version after the unit has rebooted.

To verify the active firmware version

  1. Type the following command in the CLI:
Your Product# show system information

The following information will appear:

Hardware Version                 : 500-173-01
Software Version                 : 10.04.006.00.02
Firmware Version                 : AMO-100G-NG_24.08_2800

Hardware Serial Number           : C414-0305
Software Serial Number           : 1-0-0
Switch Name                      : C414-0305
System Contact                   : Accedian, Canada
System Name                      : C414-0305
System Location                  : Accedian, Canada
Logging Option                   : Console Logging
Device Uptime                    : 0 Days, 0 Hrs, 0 Mins, 54 Secs
Login Authentication Mode        : Local
Config Save Status               : Not Initiated
Remote Save Status               : Not Initiated
Config Restore Status            : Not Initiated
Traffic Separation Control       : none

The upgrade to AMO-100G-NG_24.08_2800 is complete.

© 2024 Cisco and/or its affiliates. All rights reserved.
 
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks



Was this article helpful?

What's Next
Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.