Shutdown Interface

Prev Next

This article describes the configuration of interface P2 to raise a defect/fault in sample topology.

CLI Configurations

At Switch5

  • Make interface P2 as down.
your product(config)# interface gigabitethernet 0/2
your product(config-if)# shutdown
  • Wait for 15 seconds to check for any link failure (error/fault/defect).

SNMP Configurations

At Switch5

  • Make interface P2 as down. [Index: Interface Number = 2]
% snmp0 set {{ifMainAdminStatus.2 down}}
  • Wait for 15 seconds to check for any link failure (error/fault/defect).