- Print
- PDF
This section presents a detailed description of the CLI commands used to configure and review the configuration of the Platform Monitor application.
Command Mode | Access Method | Prompt | Exit method |
---|---|---|---|
Platform Monitor Configuration | The User EXEC mode command is used. This is the initial mode to start a session. | your product(platform-monitor)# | The logout method is used. |
Platform Monitor CLI commands are categorized as follows:
Configuration Command
This section includes the Platform Monitor configuration command.
set dry-contact
Command Objective:
This command sets the configuration parameters of the dry-contact probe.
Syntax:
set dry-contact < id > { [state {enable|disable}] [interval <100-1000>] [name <1-127 characters>] [normalstate {close|open}] }
Parameter Description:
- < id > - The dry-contact input id <1|2>
- {state <enable|disable>] - Enable/Disable the dry-contact input operational state
- {interval <100-1000>} - Interval at which the probe will collect data. From 100 to 1000 milliseconds, expressed in steps of 100 milliseconds.
- {name <1-127 characters>] - Dry-contact input name
- {normalstate {close|open}} - Normal state of the dry-contact input
Mode:
Platform Monitor Configuration
Example:
Your Product# configure terminal
Your Product(config)# dry-contact
Your Product(dry-contact)# set dry-contact 1 state enable interval 100 name Input1Active normalstate close
Display Commands
This section includes Platform Monitor display commands.
show platform-monitor
Command Objective:
This command displays Platform information.
Syntax:
show platform-monitor { cpu | cpuload | memory | fs | psu | fan | temp}
Parameter Description:
- cpu - CPU usage
- cpuload - CPU load average
- memory - Memory usage
- fs - File System usage
- psu - Power Supply
- fan - Fan
- temp - Temperature
Mode:
Privileged EXEC Mode
Example:
Your Product# show platform-monitor cpu
CPU used : 9%
show platform-monitor dry-contact configuration | status
Command Objective:
This command displays dry-contact configuration and status information.
Syntax:
show platform-monitor dry-contact {configuration | status}
Parameter Description:
- dry-contact - The dry-contact probe
- configuration | status - Configuration|Status of the dry-contact input
Displayed Parameters Description:
- Input #< id > - The dry-contact input id <1|2>
- Operational state : Enable|Disable - The dry-contact input operational state
- Normal input state : Opened|Closed - Normal state of the dry-contact input
- Interval < 100-1000 > msec - Interval at which the probe will collect data. From 100 to 1000 milliseconds.
- Name <1-127 characters> - The dry-contact input name
- Input pin state : Opened|Closed - Input pin state of the dry-contact
Mode:
Privileged EXEC Mode
Example:
Your Product# show platform-monitor dry-contact status
Dry contact input status:
Input #1 :
Operational state : Enabled
Normal input state : Closed
Input pin state : Opened
Input #2 :
Operational state : Disabled
Normal input state : ---
Input pin state : ---
Your Product# show platform-monitor dry-contact configuration
Dry contact input configuration:
Input #1 :
Operational state : Enabled
Normal input state : Closed
Interval : 100 msec
Name : Input1Active
Input #2 :
Operational state : Disabled
Normal input state : Opened
Interval : 1000 msec
Name : Input2Active
show platform-monitor transceiver
Command Objective:
This command lists transceivers connected on the unit's ports and provides high-level information for the following:
- Type
- Vendor name
- Part number
- Serial number
Syntax:
show platform-monitor transceiver
Mode:
Privileged EXEC Mode
Example:
Your Product# show platform-monitor transceiver
--------------------------------------------------------------------------------
Port Type Vendor Part Serial
Name Number Number
--------------------------------------------------------------------------------
1 100GBASE-CR4 FS Q28-PC01 G2006502622-2
2 100GBASE-SR4 Accedian 7QM-000 L2102090233
3 100GBASE-LR4 Accedian 7QN-000 L2011190077
4 100GBASE-ER4 Accedian 7QP-000 L2106250012
AUX 100G SWDM4 Gigalight 7SM-400 M110803029
show platform-monitor transceiver [port]
Command Objective:
This command provides further information for each transceiver that is set port ID: 1 to 4 or AUX (as labeled on the product's front panel):
- Temperature (C)
- Supply Voltage (V)
- Tx Bias Current (mA)
- Tx Output Power (dBm)
- Rx Optical Pwr (dBm)
- Type
- Vendor name
- Part number
- Serial number
Syntax:
show platform-monitor transceiver [port]
Parameter Description:
- port - 1 to 4 or AUX (as labeled on the product's front panel)
Mode:
Privileged EXEC Mode
Example:
Your Product# show platform-monitor transceiver 2
Transceiver in 2
Identifier : QSFP28
Transceiver Type : 100GBASE-SR4
Connector Type : MPO 1x12
Wavelength : 850nm
Encoding : 64B/66B
Signaling Rate : 25500 MBd
Transfer Distance : 70m (OM3), 100m (OM4)
Vendor Name : Accedian
Vendor OUI : 00:24:FD
Vendor PN : 7QM-000
Vendor Rev : S1
Vendor SN : L2102090233
Date Code (yy-mm-dd) : 21-02-09
Diagnostic Support : Yes
SFP memory (Location : A0H)
===============================================================================
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
000: 11 DC 0C 80 00 00 00 40 20 02 00 05 FF 00 00 23 * .......@ ......# *
016: 00 00 32 00 41 63 63 65 64 69 61 6E 20 20 20 20 * ..2.Accedian *
032: 20 20 20 20 00 00 24 FD 37 51 4D 2D 30 30 30 20 * ..$.7QM-000 *
048: 20 20 20 20 20 20 20 20 53 31 42 68 07 D0 46 5A * S1Bh..FZ *
064: 02 00 30 9A 4C 32 31 30 32 30 39 30 32 33 33 20 * ..0.L2102090233 *
080: 20 20 20 20 32 31 30 32 30 39 20 20 0C 00 67 8F * 210209 ..g. *
096: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 * ................ *
112: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 * ................ *
===============================================================================
Transceiver Digital Diagnostic Monitoring (DDM)
===============================================================================
Value Low Alarm Low Warn High Warn High Alarm
-------------------------------------------------------------------------------
Temperature (C) 29.31 0.00 5.00 65.00 70.00
Supply Voltage (V) 3.30 2.90 3.00 3.50 3.60
===============================================================================
Transceiver Lane Digital Diagnostic Monitoring (DDM)
===============================================================================
Low Alarm Low Warn High Warn High Alarm
-------------------------------------------------------------------------------
Lane Tx Bias Current (mA) 2.00 3.00 13.00 14.00
Lane Tx Output Power (dBm) -9.40 -8.40 2.40 3.40
Lane Rx Optical Pwr (dBm) -11.00 -10.60 2.40 3.40
-------------------------------------------------------------------------------
Lane ID Tx Bias(mA) Tx Pwr(dBm) Rx Pwr(dBm)
-------------------------------------------------------------------------------
1 7.00 -0.18 -1.35
2 7.00 0.05 0.17
3 7.00 0.37 0.01
4 7.00 0.13 0.40
===============================================================================
© 2024 Cisco and/or its affiliates. All rights reserved.
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms