MEP for an Ethernet Private Line Service
  • 28 Jun 2024
  • 6 Minutes to read
  • Contributors
  • PDF

MEP for an Ethernet Private Line Service

  • PDF

Article summary

Configuring Maintenance End Points for an EPL service


This use case article describes the configuration of the MEP for an Ethernet Private Line service.


Note: The Maintenance Domain and Maintenance Association must be configured prior to the configuration of the MEP.

  • Configuring of S-VLAN-aware Down MEP on NNI Port and S-VLAN-aware UP MEP on UNI Port.
  • Support for Multiple Maintenance Domain Level with MD Level of UP MEP being higher than the MD Level of Down MEP.
  • Functionality of Continuity Check (CC – for intervals of 3.3ms and 1 second), Loopback (LB), and Link Trace (LT)
  • Support for Cross-connect defect (DefXconCMM), Error-CCM defect (DefErrorCCM), Remote CCM defect (DefRemoteCCM), and RDI defect (DefRDICCM)
  • MAC Status defect (DefMACstatus) is not supported, due to its capability not being supported in Marvell chipset.

CLI Configurations

To configure MEP for an EPL service

  1. Enable CFM Global Configurations
Your Product# configure terminal
Your Product(config)# ethernet cfm start
Your Product(config)# ethernet cfm enable
Your Product(config)# ethernet cfm offload
Your Product(config)# end
Your Product#
  1. Port Configurations
Your Product# configure terminal
Your Product(config)# interface range xl-ethernet 0/1-4
Your Product(config-if-range)# shut
Your Product(config-if-range)# flowcontrol on
Your Product(config-if-range)# mtu 10240
Your Product(config-if-range)# no shut
Your Product(config-if-range)# end
  1. Bridge Port Related Configurations
Your Product# configure terminal
Your Product(config)# bridge-mode provider-edge
Your Product(config)# interface xL-ethernet 0/2
Your Product(config-if)# bridge port-type customerEdgePort
Your Product(config-if)# end
Your Product# configure terminal
Your Product(config)# interface xL-ethernet 0/1
Your Product(config-if)# bridge port-type providerNetworkPort
Your Product(config-if)# end
  1. Service VLAN Configurations
Your Product# configure terminal
Your Product(config)# vlan 6
Your Product(config-vlan)# ports xL-ethernet 0/2,0/1 untagged xL-ethernet 0/2
Your Product(config-vlan)# service-type e-line
Your Product(config-vlan)# end
Your Product#
Your Product# configure terminal
Your Product(config)# vlan 7
Your Product(config-vlan)# ports xL-ethernet 0/2,0/1 untagged xL-ethernet 0/2
Your Product(config-vlan)# service-type e-line
Your Product(config-vlan)# end
  1. Customer VLAN to service VLAN mapping configurations (EPL Service)
Your Product# configure terminal
Your Product(config)# interface xL-ethernet 0/2
Your Product(config-if)# switchport customer-vlan 100 service-vlan 6
Your Product(config-if)# switchport customer-vlan 103 service-vlan 7
Your Product(config-if)# switchport dot1q customer vlan 100
Your Product(config-if)# switchport dot1q customer vlan 103
Your Product(config-if)# end
  1. UP MEP Configurations

UP MEP-1
MA and MD level configurations

Your Product# configure terminal
Your Product(config)# ethernet cfm domain format dns-like-name name CUS5 level 5
Your Product(config-ether-ecfm)# service format char-string name CUSMA5 vlan 6
Your Product(config-ether-ecfm)# mep crosscheck mpid 9 vlan 6
Your Product(config-ether-ecfm)# mep crosscheck mpid 10 vlan 6
Your Product(config-ether-ecfm)# end
Your Product#

CCM interval with 3.3 milliseconds

Your Product# configure terminal
Your Product(config)# ethernet cfm cc level 5 vlan 6 interval three-hundred-hertz
Your Product(config)# end
Your Product#

Create UP MEP with MEP ID 9 on VLAN 6

Your Product# configure terminal
Your Product(config)# interface xl-ethernet 0/2
Your Product(config-if)# ethernet cfm mep level 5 inward mpid 9 vlan 6 active
Your Product(config-ether-mep)# end
Your Product#

Enable UP MEP CCM at level 5 on VLAN 6

Your Product# configure terminal
Your Product(config)# switch default
Your Product(config-switch)# ethernet cfm cc enable level 5 vlan 6
Your Product(config-switch)# end

UP MEP-2
MA and MD level configurations

Your Product# configure terminal
Your Product(config)# ethernet cfm domain format dns-like-name name CUS6 level 6
Your Product(config-ether-ecfm)# service format char-string name CUSMA6 vlan 6
Your Product(config-ether-ecfm)# mep crosscheck mpid 11 vlan 6
Your Product(config-ether-ecfm)# mep crosscheck mpid 12 vlan 6
Your Product(config-ether-ecfm)# end
Your Product#

CCM interval with 3.3 milliseconds

Your Product# configure terminal
Your Product(config)# ethernet cfm cc level 6 vlan 6 interval three-hundred-hertz
Your Product(config)# end
Your Product#

Create UP MEP with MEP ID 11 on VLAN 6

Your Product# configure terminal
Your Product(config)# interface xl-ethernet 0/2
Your Product(config-if)# ethernet cfm mep level 6 inward mpid 11 vlan 6 active
Your Product(config-ether-mep)# end
Your Product#

Enable UP MEP CCM at level 6 on VLAN 6

Your Product# configure terminal
Your Product(config)# switch default
Your Product(config-switch)# ethernet cfm cc enable level 6 vlan 6
Your Product(config-switch)# end

UP MEP-3
MA and MD level config

Your Product# configure terminal
Your Product(config)# ethernet cfm domain format dns-like-name name CUS7 level 7
Your Product(config-ether-ecfm)# service format char-string name CUSMA7 vlan 7
Your Product(config-ether-ecfm)# mep crosscheck mpid 13 vlan 7
Your Product(config-ether-ecfm)# mep crosscheck mpid 14 vlan 7
Your Product(config-ether-ecfm)# end
Your Product#

CCM interval with 3.3 milliseconds

Your Product# configure terminal
Your Product(config)# ethernet cfm cc level 7 vlan 7 interval three-hundred-hertz
Your Product(config)# end
Your Product#

Create UP MEP with MEP ID 13 on VLAN 7

Your Product# configure terminal
Your Product(config)# interface xl-ethernet 0/2
Your Product(config-if)# ethernet cfm mep level 7 inward mpid 13 vlan 7 active
Your Product(config-ether-mep)# end
Your Product#

Enable UP MEP CCM at level 7 on VLAN 7

Your Product# configure terminal
Your Product(config)# switch default
Your Product(config-switch)# ethernet cfm cc enable level 7 vlan 7
Your Product(config-switch)# end
  1. DOWN MEP Configurations

DOWN MEP-1
MA and MD level configurations

Your Product# configure terminal
Your Product(config)# ethernet cfm domain format dns-like-name name CUS2 level 2
Your Product(config-ether-ecfm)# service format char-string name CUSMA2 vlan 7
Your Product(config-ether-ecfm)# mep crosscheck mpid 1 vlan 7
Your Product(config-ether-ecfm)# mep crosscheck mpid 2 vlan 7
Your Product(config-ether-ecfm)# end
Your Product#

CCM interval with 3.3 milliseconds

Your Product# configure terminal
Your Product(config)# ethernet cfm cc level 2 vlan 7 interval three-hundred-hertz
Your Product(config)# end
Your Product#

Create DOWN MEP with MEP ID 1 on VLAN 7

Your Product# configure terminal
Your Product(config)# interface xl-ethernet 0/1
Your Product(config-if)# ethernet cfm mep level 2 mpid 1 vlan 7 active
Your Product(config-ether-mep)# end
Your Product#

Enable DOWN MEP CCM at level 2 on VLAN 7

Your Product# configure terminal
Your Product(config)# switch default
Your Product(config-switch)# ethernet cfm cc enable level 2 vlan 7
Your Product(config-switch)# end

DOWN MEP-2
MA and MD level configurations

Your Product# configure terminal
Your Product(config)# ethernet cfm domain format dns-like-name name CUS3 level 3
Your Product(config-ether-ecfm)# service format char-string name CUSMA3 vlan 6
Your Product(config-ether-ecfm)# mep crosscheck mpid 3 vlan 6
Your Product(config-ether-ecfm)# mep crosscheck mpid 4 vlan 6
Your Product(config-ether-ecfm)# end
Your Product#

CCM interval with 3.3 milliseconds

Your Product# configure terminal
Your Product(config)# ethernet cfm cc level 3 vlan 6 interval three-hundred-hertz
Your Product(config)# end
Your Product#

Create DOWN MEP with MEP ID 3 on VLAN 6

Your Product# configure terminal
Your Product(config)# interface xl-ethernet 0/1
Your Product(config-if)# ethernet cfm mep level 3 mpid 3 vlan 6 active
Your Product(config-ether-mep)# end
Your Product#

Enable DOWN MEP CCM at level 3 on VLAN 6

Your Product# configure terminal
Your Product(config)# switch default
Your Product(config-switch)# ethernet cfm cc enable level 3 vlan 6
Your Product(config-switch)# end

DOWN MEP-3
MA and MD level configurations

Your Product# configure terminal
Your Product(config)# ethernet cfm domain format dns-like-name name CUS4 level 4
Your Product(config-ether-ecfm)# service format char-string name CUSMA4 vlan 6
Your Product(config-ether-ecfm)# mep crosscheck mpid 5 vlan 6
Your Product(config-ether-ecfm)# mep crosscheck mpid 6 vlan 6
Your Product(config-ether-ecfm)# end
Your Product#

CCM interval with 3.3 milliseconds

Your Product# configure terminal
Your Product(config)# ethernet cfm cc level 4 vlan 6 interval three-hundred-hertz
Your Product(config)# end
Your Product#

Create DOWN MEP with MEP ID 5 on VLAN 7

Your Product# configure terminal
Your Product(config)# interface xl-ethernet 0/1
Your Product(config-if)# ethernet cfm mep level 4 mpid 5 vlan 6 active
Your Product(config-ether-mep)# end
Your Product#

Enable DOWN MEP CCM at level 4 on VLAN 6

Your Product# configure terminal
Your Product(config)# switch default
Your Product(config-switch)# ethernet cfm cc enable level 4 vlan 6
Your Product(config-switch)# end

© 2024 Cisco and/or its affiliates. All rights reserved.
 
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks



Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.