Enabling Ethernet Y.1731
  • 27 Jun 2023
  • 1 Minute to read
  • Contributors
  • PDF

Enabling Ethernet Y.1731

  • PDF

Article summary

By default, Y.1731 compliant features are in the disabled state. That is, it does not generate, receive or reply to any of the Y.1731 compliant CFM PDU(s).

ECFM must be enabled for Y.1731 to start functioning.

Y.1731 should be enabled for Y.1731 compliant features such as AIS, LCK, and so on, to start functioning.

CLI Configurations

To globally enable Y.1731

  1. Enter into the global configuration mode
    your product# configure terminal

  2. Enable CFM processing globally
    your product(config)# ethernet cfm enable

  3. Enable Y.1731 processing globally
    your product(config)# ethernet cfm y1731 enable

  4. Return to the privileged EXEC mode.
    your product(config)# exit

To globally disable Y.1731

  1. Enter into the global configuration mode and disable Y.1731 processing globally.
    your product(config)# no ethernet cfm y1731 enable

SNMP Configurations

  1. Enable Y.1731 processing globally [Index: ContextID = 0].
    % snmp0 set {{fsMIEcfmModuleStatus.0 enabled }}
    % snmp0 set {{fsMIY1731OperStatus.0 enabled }}
  2. Disable Y.1731 processing globally [Index: ContextID = 0].
    % snmp0 set {{fsMIY1731OperStatus.0 disabled }}

© 2024 Cisco and/or its affiliates. All rights reserved.
 
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks



Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.