This article describes the steps to configure and enable the transmission and reception of TST PDU by an MEP.
CLI Configurations
To configure and enable test messages
-
Execute the steps given in CLI Configurations to configure MEP before sending the test messages.
-
Execute the steps given in section CLI Configurations to enable ECFM and Y.1731 for Y.1731 test message feature.
-
Send the TST message to an MEP using destination’s MAC address.
your product# ethernet cfm test mac 00:02:02:03:04:03 level 7 vlan 101 count 5
TST to 00:02:02:03:04:03 from 00:01:02:03:04:03 with 33(64) bytes of data.
60 bytes to 00:02:02:03:04:03: seq_no=0
60 bytes to 00:02:02:03:04:03: seq_no=1
60 bytes to 00:02:02:03:04:03: seq_no=2
60 bytes to 00:02:02:03:04:03: seq_no=3
60 bytes to 00:02:02:03:04:03: seq_no=4
--- 00:02:02:03:04:03 test statistics ---
packets sent = 5 with prbs signal without crc32 pattern
your product#
For sending a Test message to an MEP using destination’s MEPID
Example: ethernet cfm test mpid 2 level 6 vlan 5 count 5
-
If the user does not provide target MPID and MAC Address, it will be treated as multicast TST messages.
-
For a VLAN-UnAware MEP, vlan keyword must not be provided with the command.
-
ECFM and Y.1731 should be enabled for the successful Test message transmission.
-
count and deadline keyword, if not provided, assumes infinite number of test messages to send.
SNMP Configurations
To configure and enable test messages
-
Execute the steps given in SNMP Configurations to configure MEP before sending the test messages.
-
Execute the steps given in SNMP Configurations to enable ECFM and Y.1731 for Y.1731 test message feature.
-
Send the TST message to an MEP using destination MAC address. [Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-Index = 5]
%snmp0 set {{fsMIY1731MepTransmitTstDestMacAddress.0.1.1.5 00:02:02:03:04:03 }}
%snmp0 set {{fsMIY1731MepTransmitTstMessages.0.1.1.5 5 }}
%snmp0 set {{fsMIY1731MepTransmitTstStatus.0.1.1.5 start }}
Note: MEP at specified level and VLAN must be enabled for a test transaction. The test capability can be enabled using the following steps:
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-Index = 5]
% snmp0 set {{fsMIY1731MepRowStatus.0.1.1.5 notInService }}
% snmp0 set {{fsMIY1731MepTstCapability.0.1.1.5 enabled }}
% snmp0 set {{fsMIY1731MepRowStatus.0.1.1.5 active }}