Configuring and Enabling Lock Messages
  • 27 Jun 2023
  • 1 Minute to read
  • Contributors
  • PDF

Configuring and Enabling Lock Messages

  • PDF

Article summary

This article describes the steps to configure and enable the transmission of LCK PDU by an MEP.

CLI Configurations

To configure and enable LCK message

  1. Execute the steps given in CLI Configurations to configure MEP before sending the LCK messages.

  2. Execute the steps given in CLI Configurations to enable ECFM and Y.1731 on the interface at which MEP is configured.

  3. Configure client layer level.
    your product# configure terminal
    your product(config)# ethernet cfm domain name TestDomain1 level 3
    your product (config-ether-ecfm)# client-layer-level 6
    your product# end

  4. Enable LCK capability on the MEP, so that when any defect occurs, the MEP starts transmitting the LCK to all the MEP(s) configured at the client layer level.
    your product# configure terminal
    your product(config)# interface gigabitethernet 0/10
    your product(config-if)# ethernet cfm mep level 3 inward mpid 4 vlan 5 active
    your product(config-ether-mep)# set out-of-service enable
    your product(config-ether-mep)# end


Notes:
Client layer level must be configured before enabling LCK capability.
Client layer level should be greater than the server level.
LCK can be sent as unicast messages by configuring its unicast MAC address using the set client-layer-mac lck unicast command. (This command runs in ECFM Mep configuration Mode.)
Example:
set client-layer-mac lck unicast 00:01:02:03:04:06

© 2024 Cisco and/or its affiliates. All rights reserved.
 
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks



Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.