Viewing Y.1564 Test Results
  • 19 Sep 2024
  • 4 Minutes to read
  • Contributors
  • PDF

Viewing Y.1564 Test Results

  • PDF

Article summary

You can view the results for all the tests being run by Legacy orchestrator. The reports are saved on the Legacy orchestrator server.

To view Y.1564 test results

Access the page Service Performance ▶ Y.1564 ▶ Results to view the list of all tests currently being performed or executed by Legacy orchestrator.
24.09_Viewing Y.1564 Test Results_1.png

For more information on specific parameters, see the following table.

Y.1564 Test Result List (Y.1564 ▶ Results)

ParameterDescription
Test nameThe name of the Y.1564 test.
DescriptionA description to identify the Y.1564 test and its characteristics.
Source device nameThe name of the source device for this test.
OperatorThe name of the user who executed the test.
Status
  • UNSTARTED: The test has not been started yet.
  • INPROGRESS: The test is running.
  • PASSED: The test was completed successfully.
  • CANCELED: The test was canceled before completion.
  • FAILED: The test failed.
Start timeThe timestamp indicating when the test began.
End timeThe timestamp indicating when the test ended.
Force deleteSelect this option to ensure the immediate removal of any test configurations that were deleted locally. Will not wait for the next synchronization process to complete.

If a test configuration is deleted directly from a device (using the web interface or a CLI command on the device itself), a subsequent request on Legacy orchestrator to delete this test configuration will result in an error message stating that the test is not present on the device.

In the event of such an error, Legacy orchestrator will leave the test configuration in its database. Legacy orchestrator will detect the deletion of the test configuration on the device during its normal synchronization process. Then it will synchronize its data store to remove the configuration from its inventory.

However, if you want to force this test to be deleted immediately, simply select the Force delete option.

Viewing a Y.1564 Test Summary

The status summary shows a quick overview of the Y.1564 Test.

To view a summary of a Y.1564 test

  1. Access the Service Performance ▶ Y.1564 ▶ Results page.

  2. Select a test result.


    Note: You can select several test results by holding the Ctrl or Shift key on your keyboard as you click.

  3. Click the Show Y.1564 Test Status Button_ShowY1564TestStatus.png button. The status dialog is displayed.

For more information on specific parameters, refer to the table "Y.1564 Status Summary (Y.1564 ▶ Results)".
If more than one test was selected, subsequent status summaries are appended.

Viewing Detailed Y.1564 Test Results

Detailed results of a Y.1564 test are stored in a file. The results of tests being run through Legacy orchestrator are sent to the Legacy orchestrator server once completed. When the Legacy orchestrator server recuperates the file, it is automatically deleted from the NE.

To display the detailed results of a Y.1564 test

  1. Access the page Service Performance ▶ Y.1564 ▶ Results.

  2. Select a test result. You may select several test results by clicking and pressing down on the CTRL or the SHIFT key on your keyboard.

  3. Click the Show Y.1564 test report Button_ShowY1564TestReport.png button. The Y.1564 test report dialog is displayed.

If more than one test was selected, subsequent reports are appended in the Y.1564 Test Report dialog.
From the dialog, you can export the report by clicking the Export button.

Exporting Y.1564 Test Results

You can export the detailed results of a Y.1564 Test to a TXT or PDF file.

To export the detailed results of a Y.1564 test

  1. Access the page Service Performance ▶ Y.1564 ▶ Results.

  2. Select a test result. You may select several test results by clicking and pressing on the Ctrl or Shift key on your keyboard.

  3. Click the Export Y.1564 Report EXPORT BUUTTON.png button.

  4. Select the export file format PDF or Text.

  5. Click the Export button.
    A dialog pops up allowing you to save the file.

  6. Save the file under the name and location of your choice.

Test Summary Dashboard

The test summary dashboard gives you a high-level statistical view of the Y.1564 test status, test duration, and finished tests. The dashboard is displayed on the bottom of the Results page. Clicking on the text summaries will create a filter on the grid.
24.09_Viewing Y.1564 Test Results_2.PNG


Notes:

Text summaries have replaced pie charts as of Legacy orchestrator 23.12.

The Test status and Finished test filter is the same as operationalState and lastUpdate chart in Devices tab of Managed Elements.


The Test duration chart filter has two fields representing a time range in hours. Each field will receive a number from 0 to 24, meaning 0 hour to 24 hours. Fields must be in ascending order.

The dashboard provides you with the following statistics:

TypeText SummaryDetails
Test statusViewing Y.1564 Test Results_3 test status.PNGDisplays the status of the tests, in percentages.

Status includes:

  • Passed
  • Failed
  • Cancelled
  • In progress
  • Unstarted
  • Unknown
Test durationViewing Y.1564 Test Results_4 test duration.PNGDisplays the duration of tests, in percentages.

Duration includes:

  • 0h to 1h
  • 1h to 6h
  • 6h to 12h
  • 12h to 24h
  • more than 24h
  • N/A
Finished testViewing Y.1564 Test Results_5 finished test.PNGDisplays the tests that have finished, in percentages.

Finished time includes:

  • last 12 hours
  • 12h to 24h
  • more than 24h
  • N/A

© 2024 Cisco and/or its affiliates. All rights reserved.
 
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks



Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.