- Print
- PDF
Viewing Loop Detection Counter Instances
Use this page to view the statistical counters that provide an overview of the loop detection instances created on the unit.
To view the counters of all loop detection instances
Access the page Loop Detection ►Counters ►Instances.
A summary of all loop detection instances that have been configured is displayed. The total number of instances found in the system is given in the lower-left corner of the page, as well as the index values of the items currently displayed on-screen (for example, [1–25] of 54). Use the page navigation links in the lower-right corner of the page to move between the pages of results.(Optional) To clear the counters for all loop detection instances at the same time, click the Clear button.
Click the Name of an existing loop detection instance to view its counters' details.
Tip: Select the Poll Every n Seconds box, then enter a number representing the frequency with which the loop detection instance’s counters will be automatically refreshed. You can also update the counters manually by clicking the Refresh button.
For more information on specific parameters, refer to the following table.
Loop Detection Counters (Loop Detection ►Counters ►Instances)
Parameter | Description |
---|---|
Index | The unique identifier assigned to the loop detection instance. You cannot modify this value. |
Name | The name used to uniquely identify the loop detection instance. |
State | The state of this loop detection instance. Acceptable values are either Enabled or Disabled. |
Type | The type of loop detection instance. Acceptable values are:
|
Resource | The name of the physical/logical port or interface polled by this loop detection instance. |
Sent Frames | The total number of loop detection beacons that have been transmitted by this instance, but have not returned. This value is calculated for the period since either the loop detection instance was created or since the counters were last cleared, whichever is more recent. |
Received Frames | The total number of loop detection beacons that have been transmitted and received by this instance. This value is calculated for the period since either the loop detection instance was created or since the counters were last cleared, whichever is more recent. Note: The number of received frames does not always equal the number of loop detected frames. A frame could be received for reasons other than a detected loop, such as a change of VLAN ID. |
Loop Detected Frames | The total number of loop detection beacons transmitted by this instance that have successfully detected a loop on the specified resource. This value is calculated for the period since either the loop detection instance was created or since the counters were last cleared, whichever is more recent. |
© 2024 Cisco and/or its affiliates. All rights reserved.
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms
For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks