Skylight Flex 25 Release Notes 23.09
  • 05 Feb 2024
  • 5 Minutes to read
  • Contributors
  • Dark
    Light
  • PDF

Skylight Flex 25 Release Notes 23.09

  • Dark
    Light
  • PDF

Article Summary

Overview

Accedian is pleased to announce the 23.09 GA release of Skylight Flex 25. This software runs on the 25G platform.

Product NameSoftware VersionBuild NumberSoftware Files
Skylight Flex 2523.09 GA2201

AAMO-25G-NG_23.09_2201.afl.startup

AMO-25G-NG_23.09_2201.afl

Accedian_MIB_2201

The following components have been tested:

  • uBoot version 217
  • CPLD version 315
  • Skylight orchestrator 23.04.1
  • RR Standalone version 0.456.18, Shipper 0.20.0
  • roadrunner_sal_bundle_0.32.11
  • RoadRunner Connected version 0.456.19
  • Skylight Analytics 23.04.137 (aod-deployer 11.175.138)

The following topics are covered in this article:

  • Supported Features
    Covers Skylight Flex 25’s supported features.

  • Support in Release 23.09
    Details the support for scalability and transceivers.

  • Operational Considerations
    Lists the operational considerations for Skylight Flex 25.

  • Skylight Flex 25 Release 23.09 Lifecycle
    Details the life cycle for this release.

For more information, such as the initial configuration guidelines and upgrade procedure, see Getting Started.

Supported Features

The following key features are supported by Skylight Flex 25 in release 23.09:

Device Infrastructure and Management Features

  • SNMP (v2c, v3) agent and MIB support
  • NETCONF support
  • Configuration Save and Restore
  • CLI (Console, SSH), multiple user privilege levels
  • DHCP client - IPv4
  • DNS client - IPv4
  • Syslog client and relay agent – IPv4
  • Configuration upgrade through TFTP or SFTP file transfer – IPv4 and IPv6
  • IP authorized managers – IPv4
  • Management RJ45 port 10M, 100M and 1G
  • Auxiliary port 1G and 10G
  • Traffic port 10G and 25G
  • Jumbo frame support
  • Auto-negotiation of speed and duplex modes
  • Zero Touch Provisioning
  • PM Telemetry
  • Platform Monitor

Basic Layer 2 Ethernet Connectivity Features

  • 802.3x flow control
  • CPU rate limitation for storm protection
  • Rate limiting
  • Port mirroring
  • 802.1Q Customer VLAN bridging functionality
  • LLDP
  • RMONv1 – statistics, history, alarm, event
  • ACLs (Access Control Lists) – L2 (Ethernet header) for traffic filtering
  • Link Aggregation (802.3ad)

Advanced Layer 2 Ethernet Switching Features

  • 802.1Q Provider Bridge Functionality
  • Ethernet CFM 802.1ag, Y.1731
  • Basic E-LINE Ethernet Services creation
  • VLAN translation support
  • MEF 10.2 and 10.3 bandwidth regulator
  • Layer 2 Flow Filtering based on multiple VLAN headers
  • VLAN Header Re-marking in double tagged scenario
  • E-LINE Ethernet Services – 2 TAG support
  • Active Standby Link Protection using LAG (LACP)
  • E-SAT – Y.1564
    • Simple CIR Test
    • Step Load CIR Test
    • EIR Configuration Test
    • Traffic Policing Test
    • Frame Transfer Delay (FTD) values in microsecond precision for both SAC configuration and report
    • Frame Delay Variations (FDV) values in microsecond precision for both SAC configuration and report
    • Frame Loss Ratio (FLR) configuration in SAC profile is extended to support fractional value (example: 0.01%)
    • Layer 1 and Layer 2 Flow configuration support
    • Layer 2 standard frame format support, providing interoperability with third party loopback applications
    • Maximum SLA session creation has been extended to 100 with ID ranges from 1 to 100; the maximum number of active/concurrent SAT sessions running in the system is 10
  • L2CP frame transparency mode support
  • Facility Loopback for SAT testing
  • ETH-SLM and ETH-DMM
  • ETH-CSF

Support in Release 23.09

Scalability Support

The following table contains the details of scalability tested in this release:

Scalability ParametersScalability Value
Max number of CLI users on one device​15
Max number of simultaneous SSH/Telnet sessions8
Max L2 Filter entries246
Max L3 Filter entries256
Max QoS Policy map512
Max QoS Meters512

Note: Supported QoS Meter ID from 1 to 1,000.

Max Y.1564 services supported100
Number of EVC Entries1000
Number of MEPs supported in the systemTotal UP MEP supported – 1000

Total Down MEP supported – 1000​

Total UP MEP and Down MEP together supported - 1000

PM-SLM / DMMTotal UP MEP supported – 1000

Each MEP supports up to 3 SLM Sessions and 3 DMM Sessions

With 1000 MEP, 3000 SLM Sessions and 3000 DMM Sessions

25GE Flex Supported Transceivers

The following table details the supported transceivers for this release:


Note: RS-FEC is not currently supported on Flex. Refer to the QSFP28 (Flex 100) and SFP28 (Flex 25) manufacturers datasheets for the maximum reach without RS-FEC.

Transceiver TypeProduct SKUAuxiliary PortTraffic Port
SFP28, 25GBASE-SR, 850nm, OM4 : 100m7PM-000Not ApplicableSupported
SFP+, 10GBASE-BR, 1270-1330nm, 10km

SFP+, 10GBASE-BR, 1330-1270nm, 10km

7ST-400 / 7SU-400Not ApplicableSupported
SFP28, 25GBASE-LR, 1310nm, OS2: 10km7PN-000Not ApplicableSupported
SFP28, 25GBASE-ER, 1310nm, OS2: 40km7PP-000Not ApplicableSupported
SFP+, 10GBASE-SR, 850nm, OM3: 300m7SM-400SupportedSupported
SFP+, 10GBASE-BR, 1270-1330nm, 10km

SFP+, 10GBASE-BR, 1330-1270nm, 10km

7ST-400 / 7SU-400SupportedSupported
SFP+, 10GBASE-LR, 1310nm, OS2: 10km7SN-400SupportedSupported
SFP+, 10GBASE-ER, 1550nm, 40km7SP-500SupportedSupported
SFP+, 10GBASE-ZR, 1550nm, 80km7SP-402SupportedSupported
SFP, 1000BASE-SR, 850nm, 550m7SM-000SupportedNot Applicable
SFP, 1000BASE-LR, 1310nm, 10km7SN-000SupportedNot Applicable
SFP, 1000BASE-SX, 850nm, OM2: 550m7SM-000SupportedNot Applicable
SFP, 1000BASE-LX10, 1310nm, OSx: 10km7SN-100SupportedNot Applicable
SFP, 1000BASE-BX, 1310-1490nm, 10km

SFP, 1000BASE-BX, 1490-1310nm, 10km

7ST-000 / 7SU-000SupportedNot Applicable
SFP, 1000BASE-ZX, 1550nm, 70km7SR-000SupportedNot Applicable
SFP, 1000BASE-EX, 1550nm, OSx: 50km7SP-000SupportedNot Applicable
SFP, 1000BASE-T, Cat 5: 100m7SV-000SupportedNot Applicable

Operational Considerations

This section documents the operational considerations related to Skylight Flex 25 release 23.09.

Access Control List Considerations

The order of operation/matching of ACL rules is based on the order of the ACL configuration; a separate field/configuration to specify priority of the ACL is not supported.

ACLs associated with the port, when requiring modification, will have to be deleted and reconfigured with updated field value.

Skylight Flex 25 Release 23.09 Lifecycle

This section lists the planned lifecycle dates of this software release. See the table below outlining the following milestones:

MilestoneDescriptionDate
General AvailabilityDate where the product is available for general field deployment for both new installations and upgrades.2023-09-12
End of Security SupportDate where security patches will no longer be delivered for this release. Any correctives for security defects required after this date will be delivered using the next major release of the software.Next Major Release
Last Time Buy / Last Time ShipDate where this release can no longer be purchased from Accedian.2024-09-12
End of Product SupportDate where functional patches will no longer be delivered for this release. Any correctives for functional defects required after this date will be delivered using the next major release of the software.2024-09-12
End of Technical SupportDate where technical assistance is no longer available from the Accedian Technical Assistance Center for this release.2028-09-12

© 2024 Accedian Networks Inc. All rights reserved. Accedian®, Accedian Networks®,  the Accedian logo™, Skylight™, Skylight Interceptor™ and per-packet intel™, are trademarks or registered trademarks of Accedian Networks Inc. To view a list of Accedian trademarks visit: http://accedian.com/legal/trademarks/. 


Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.