About Virtual Connection Endpoints (VCEs)

A Virtual Connection Endpoint (VCE) defines the NFV-based interface to use when generating NFV-based probe sessions via Skylight orchestrator. The VCE defines the NFV IP address and VLAN header for a specific remote device. When probes are generated using a VCE, the NFV IP address and VLAN header are used to encapsulate the packets associated with the probe sessions to be generated. The VCE type is also used to determine how to construct the bridge component and component ID required for Connectivity Fault Management (CFM).

The special features of a VCE include:

  • A separate, dedicated IP domain for each VCE. The domain includes the VCE's default gateway and can include static routes.
  • A VCE typically operates at Layer 2 but can also operate at Layer 3.
  • Two termination points (TP A and TP Z) that support VLAN tagging actions on probe frames.
  • A VCE can perform one of the following actions on the VLAN tags in probe frames:
    • tag: Add a VLAN tag to untagged frames
    • translate: Change the VLAN ID of tagged frames
    • untag: Remove a VLAN tag from tagged frames
    • preserve: Keep the VLAN tag of tagged frames
    • none: Do not perform any action

For NFV probes, a single VCE can only perform one action. For CFM, it is possible to concatenate several VCEs to perform a series of actions.

  • A VCE will respond to a ping or trace route request.

A VCE can be used to generate and manage multiple NFV-based probe sessions. VCEs support IPv4 and IPv6 addresses.

In order to set up an NFV TWAMP or NFV ETH-DMM session on a Skylight module through Skylight orchestrator, a suitable VCE must have been defined for the Skylight module on the sensor: control instance.

This article explains how to set up VCEs. For more information about setting up NFV sessions on Skylight , see the Skylight orchestrator Features/User Material section.

Parts of a VCE

The VCE is based on the 802.1Q bridge component. It consists of the following three parts:

  • TP A: A virtual port on the incoming side of the Skylight module. It can be on the UNI (User Network Interface) or the NNI (Network Network Interface) side of the module. By default TP A is UNI.
  • Relay: An action that will be performed on the VLAN tagging of incoming frames.
  • TP Z: A virtual port on the outgoing side of the module. It can be on the UNI (User Network Interface) or the NNI (Network Network Interface) side of the module. By default TP Z is NNI.
    image.png

© 2024 Accedian Networks Inc. All rights reserved. Accedian®, Accedian Networks®,  the Accedian logo™, Skylight™, Skylight Interceptor™ and per-packet intel™, are trademarks or registered trademarks of Accedian Networks Inc. To view a list of Accedian trademarks visit: http://accedian.com/legal/trademarks/. 


Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.