CLI Configurations

At Switch1

  • Display the details of all the MEPs and MIPs.
your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID  DomainName   Level  VLAN  Type  Port  CC-Status
     ServiceName         ISID   Dir   MAC    MP-Status
------------------------------------------------------
1    OP7              7      2    MEP   Gi0/2  Enabled
      maop7              -      Down 00:01:02:03:04:02 Active

At Switch2

  • Display the details of all the MEPs and MIPs.
your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID  DomainName    Level  VLAN  Type  Port  CC-Status
      ServiceName          ISID  Dir   MAC   MP-Status
------------------------------------------------------
5     OQ2           2      4     MEP   Gi0/2   Enabled
      maop2             -        Up  00:02:02:03:04:02  Active
3     OP4          4      4     MEP   Gi0/2    Enabled
      maop4            -        Up   00:02:02:03:04:02  Active
-     -           7      4      MIP   Gi0/2       -
      -                 -        -   00:02:02:03:04:02  Active
-     OQ2         2      4     MIP   Gi0/3         -
      maop2              -     -     00:02:02:03:04:03  Active

At Switch3

  • Display the details of all the MEPs and MIPs.
your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID  DomainName   Level  VLAN  Type  Port  CC-Status
      ServiceName        ISID   Dir   MAC   MP-Status
------------------------------------------------------
-     OQ2                2     4      MIP   Gi0/2  
     maop2             -      -   00:03:02:03:04:02 Active
6     OQ2              2      4       MEP   Gi0/3  Enabled
      maop2                 -         Up  00:03:02:03:04:03  Active
-     -                4      4      MIP   Gi0/3   -
      -              -       -     00:03:02:03:04:03  Active

At Switch5

  • Display the details of all the MEPs and MIPs.
your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID  DomainName  Level  VLAN  Type  Port    CC-Status
      ServiceName        ISID  Dir   MAC     MP-Status
------------------------------------------------------
2     OP7         7      2      MEP   Gi0/2    Enabled
      maop7                     Down 00:05:02:03:04:02  Active

At Switch6

  • Display the details of all the MEPs and MIPs.
your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID  DomainName   Level  VLAN  Type  Port  CC-Status
      ServiceName         ISID  Dir   MAC   MP-Status
------------------------------------------------------
5     OQ2           2      4    MEP   Gi0/2    Enabled
      maop2            -        Up   00:06:02:03:04:02  Active
4     OP4           4      4    MEP   Gi0/2    Enabled
      maop4          -           Up  00:06:02:03:04:02  Active
-     -             7      4     MIP   Gi0/2       -
      -                -        -   00:06:02:03:04:02  Active
-     OQ2           2      4     MIP   Gi0/3      -
      maop2      -        -     00:06:02:03:04:03 Active

At Switch7

  • Display the details of all the MEPs and MIPs.

your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID  DomainName  Level  VLAN   Type  Port  CC-Status
      ServiceName        ISID   Dir   MAC   MP-Status
------------------------------------------------------

-     OQ2          2      4    MIP   Gi0/2        -
      maop2          -        -     00:07:02:03:04:02  Active
6     OQ2          2      4    MEP   Gi0/3   Enabled
      maop2        -          Up  00:07:02:03:04:03  Active
-     -           4      4   MIP   Gi0/3        -
      -               -     00:07:02:03:04:03  Active

At Switch1, Switch2, Switch3, Switch5, Switch6, Switch7

  • Wait for 15 seconds and check for any defect/fault
your product# show ethernet cfm errors
your product#

Shows no link failure, as no error is detected at any of the bridges.

SNMP Configurations

At Switch1

  • Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:37}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 7}
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1]
% snmp0 get {fsMIEcfmMaFormat.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.1.1 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.1.1 {OCTET STRING} 6D:61:6F:70:37}
% snmp0 get {fsMIEcfmMaCcmInterval.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.1.1 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.1.1 INTEGER 2}
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-ID = 1]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.1.1.1}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.1.1.1 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.1.1.1}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.1.1.1 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.1.1.1}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.1.1.1 INTEGER down}
% snmp0 get {fsMIEcfmMepActive.0.1.1.1}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.1.1.1 INTEGER true}
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.1.1.1}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.1.1.1 INTEGER true}

At Switch2

  • Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:37}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 7}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 4}
[Index: Interface Number = 2, MD-level = 7, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.2.7.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.2.7.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2]
% snmp0 get {fsMIEcfmMdFormat.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.2 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.2 {OCTET STRING} 4F:50:34}
% snmp0 get {fsMIEcfmMdMdLevel.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.2 INTEGER 4}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2]
% snmp0 get {fsMIEcfmMaFormat.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.2.2 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.2.2 {OCTET STRING} 6D:61:6F:70:34}
% snmp0 get {fsMIEcfmMaCcmInterval.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.2.2 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.2.2 INTEGER 4}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 3]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.2.2.3}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.2.2.3 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.2.2.3}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.2.2.3 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.2.2.3}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.2.2.3 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.2.2.3}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.2.2.3 INTEGER true}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 4}
[Index: ContextID = 0, MD-Index = 3]
% snmp0 get {fsMIEcfmMdFormat.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.3 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.3 {OCTET STRING} 4F:50:32}
% snmp0 get {fsMIEcfmMdMdLevel.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.3 INTEGER 2}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3]
% snmp0 get {fsMIEcfmMaFormat.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.3.3 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.3.3 {OCTET STRING} 6D:61:6F:70:32}
% snmp0 get {fsMIEcfmMaCcmInterval.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.3.3 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.3.3 INTEGER 4}
% snmp0 get {fsMIEcfmMaMhfCreation.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.5.0.3.3 INTEGER defMHFdefault}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.3.3.5 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.3.3.5 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.3.3.5 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.3.3.5 INTEGER true}
[Index: Interface Number = 3, MD-level = 2, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.3.2.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.3.2.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.3.3.5}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.3.3.5 INTEGER true}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 3]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.2.2.3}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.2.2.3 INTEGER true}

At Switch3

  • Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:34}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 4}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 2}
[Index: Interface Number = 3, MD-level = 4, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.3.4.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.3.4.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2]
% snmp0 get {fsMIEcfmMdFormat.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.2 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.2 {OCTET STRING} 4F:50:32}
% snmp0 get {fsMIEcfmMdMdLevel.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.2 INTEGER 2}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2]
% snmp0 get {fsMIEcfmMaFormat.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.2.2 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.2.2 {OCTET STRING} 6D:61:6F:70:32}
% snmp0 get {fsMIEcfmMaCcmInterval.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.2.2 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.2.2 INTEGER 4}
% snmp0 get {fsMIEcfmMaMhfCreation.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.5.0.2.2 INTEGER defMHFdefault}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 6]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.2.2.6 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.2.2.6 INTEGER 3}
% snmp0 get {fsMIEcfmMepDirection.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.2.2.6 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.2.2.6 INTEGER true}
[Index: Interface Number = 2, MD-level = 2, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.2.2.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.2.2.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 6]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.2.2.6}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.2.2.6 INTEGER true}

At Switch5

  • Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:37}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 7}
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1]
% snmp0 get {fsMIEcfmMaFormat.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.1.1 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.1.1 {OCTET STRING} 6D:61:6F:70:37}
% snmp0 get {fsMIEcfmMaCcmInterval.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.1.1 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.1.1 INTEGER 2}
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-ID = 2]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.1.1.2}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.1.1.2 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.1.1.2}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.1.1.2 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.1.1.2}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.1.1.2 INTEGER down}
% snmp0 get {fsMIEcfmMepActive.0.1.1.2}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.1.1.2 INTEGER true}
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.1.1.2}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.1.1.2 INTEGER true}

At Switch6

  • Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:37}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 7}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 4}
[Index: Interface Number = 2, MD-level = 7, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.2.7.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.2.7.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2]
% snmp0 get {fsMIEcfmMdFormat.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.2 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.2 {OCTET STRING} 4F:50:34}
% snmp0 get {fsMIEcfmMdMdLevel.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.2 INTEGER 4}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2]
% snmp0 get {fsMIEcfmMaFormat.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.2.2 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.2.2 {OCTET STRING} 6D:61:6F:70:34}
% snmp0 get {fsMIEcfmMaCcmInterval.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.2.2 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.2.2 INTEGER 4}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 4]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.2.2.4}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.2.2.4 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.2.2.4}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.2.2.4 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.2.2.4}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.2.2.4 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.2.2.4}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.2.2.4 INTEGER true}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 4}
[Index: ContextID = 0, MD-Index = 3]
% snmp0 get {fsMIEcfmMdFormat.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.3 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.3 {OCTET STRING} 4F:50:32}
% snmp0 get {fsMIEcfmMdMdLevel.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.3 INTEGER 2}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3]
% snmp0 get {fsMIEcfmMaFormat.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.3.3 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.3.3 {OCTET STRING} 6D:61:6F:70:32}
% snmp0 get {fsMIEcfmMaCcmInterval.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.3.3 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.3.3 INTEGER 4}
% snmp0 get {fsMIEcfmMaMhfCreation.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.5.0.3.3 INTEGER defMHFdefault}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.3.3.5 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.3.3.5 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.3.3.5 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.3.3.5 INTEGER true}
[Index: Interface Number = 3, MD-level = 2, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.3.2.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.3.2.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.3.3.5}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.3.3.5 INTEGER true}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 4]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.2.2.4}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.2.2.4 INTEGER true}

At Switch7

  • Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:34}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 4}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 2}
[Index: Interface Number = 3, MD-level = 4, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.3.4.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.3.4.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2]
% snmp0 get {fsMIEcfmMdFormat.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.2 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.2 {OCTET STRING} 4F:50:32}
% snmp0 get {fsMIEcfmMdMdLevel.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.2 INTEGER 2}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2]
% snmp0 get {fsMIEcfmMaFormat.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.2.2 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.2.2 {OCTET STRING} 6D:61:6F:70:32}
% snmp0 get {fsMIEcfmMaCcmInterval.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.2.2 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.2.2 INTEGER 4}
% snmp0 get {fsMIEcfmMaMhfCreation.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.5.0.2.2 INTEGER defMHFdefault}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 6]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.2.2.6 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.2.2.6 INTEGER 3}
% snmp0 get {fsMIEcfmMepDirection.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.2.2.6 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.2.2.6 INTEGER true}
[Index: Interface Number = 2, MD-level = 2, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.2.2.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.2.2.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 6]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.2.2.6}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.2.2.6 INTEGER true}

At Switch1, Switch2, Switch3, Switch5, Switch6, Switch7

  • Wait for 15 seconds and check for any defect/fault
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-ID = 1]
% snmp0 get {fsMIEcfmMepDefects.0.1.1.1}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.1.1.1 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 3]
% snmp0 get {fsMIEcfmMepDefects.0.2.2.3}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.2.2.3 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmMepDefects.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.3.3.5 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 6]
% snmp0 get {fsMIEcfmMepDefects.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.2.2.6 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-ID = 2]
% snmp0 get {fsMIEcfmMepDefects.0.1.1.2}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.1.1.2 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 4]
% snmp0 get {fsMIEcfmMepDefects.0.2.2.4}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.2.2.4 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmMepDefects.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.3.3.5 {OCTET STRING} 00}

Shows no link failure, as no error is detected at any of the bridges.

© 2024 Cisco and/or its affiliates. All rights reserved.
 
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks



Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.