Verifying the Configured MPs (MEP, MIP)
- 27 Jun 2023
- 10 Minutes to read
- Contributors
- Print
- PDF
Verifying the Configured MPs (MEP, MIP)
- Updated on 27 Jun 2023
- 10 Minutes to read
- Contributors
- Print
- PDF
Article summary
Did you find this summary helpful?
Thank you for your feedback
This article describes how to verify the configured MD, MA, and MEPs.
CLI Configurations
At Switch1
- Display the details of all the MEPs and MIPs.
your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID DomainName Level VLAN Type Port CC-Status
ServiceName ISID Dir MAC MP-Status
------------------------------------------------------
1 OP7 7 2 MEP Gi0/2 Enabled
maop7 - Down 00:01:02:03:04:02 Active
At Switch2
- Display the details of all the MEPs and MIPs.
your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID DomainName Level VLAN Type Port CC-Status
ServiceName ISID Dir MAC MP-Status
------------------------------------------------------
5 OQ2 2 4 MEP Gi0/2 Enabled
maop2 - Up 00:02:02:03:04:02 Active
3 OP4 4 4 MEP Gi0/2 Enabled
maop4 - Up 00:02:02:03:04:02 Active
- - 7 4 MIP Gi0/2 -
- - - 00:02:02:03:04:02 Active
- OQ2 2 4 MIP Gi0/3 -
maop2 - - 00:02:02:03:04:03 Active
At Switch3
- Display the details of all the MEPs and MIPs.
your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID DomainName Level VLAN Type Port CC-Status
ServiceName ISID Dir MAC MP-Status
------------------------------------------------------
- OQ2 2 4 MIP Gi0/2
maop2 - - 00:03:02:03:04:02 Active
6 OQ2 2 4 MEP Gi0/3 Enabled
maop2 - Up 00:03:02:03:04:03 Active
- - 4 4 MIP Gi0/3 -
- - - 00:03:02:03:04:03 Active
At Switch5
- Display the details of all the MEPs and MIPs.
your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID DomainName Level VLAN Type Port CC-Status
ServiceName ISID Dir MAC MP-Status
------------------------------------------------------
2 OP7 7 2 MEP Gi0/2 Enabled
maop7 Down 00:05:02:03:04:02 Active
At Switch6
- Display the details of all the MEPs and MIPs.
your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID DomainName Level VLAN Type Port CC-Status
ServiceName ISID Dir MAC MP-Status
------------------------------------------------------
5 OQ2 2 4 MEP Gi0/2 Enabled
maop2 - Up 00:06:02:03:04:02 Active
4 OP4 4 4 MEP Gi0/2 Enabled
maop4 - Up 00:06:02:03:04:02 Active
- - 7 4 MIP Gi0/2 -
- - - 00:06:02:03:04:02 Active
- OQ2 2 4 MIP Gi0/3 -
maop2 - - 00:06:02:03:04:03 Active
At Switch7
- Display the details of all the MEPs and MIPs.
your product# show ethernet cfm maintenance-point local
------------------------------------------------------
MPID DomainName Level VLAN Type Port CC-Status
ServiceName ISID Dir MAC MP-Status
------------------------------------------------------
- OQ2 2 4 MIP Gi0/2 -
maop2 - - 00:07:02:03:04:02 Active
6 OQ2 2 4 MEP Gi0/3 Enabled
maop2 - Up 00:07:02:03:04:03 Active
- - 4 4 MIP Gi0/3 -
- - 00:07:02:03:04:03 Active
At Switch1, Switch2, Switch3, Switch5, Switch6, Switch7
- Wait for 15 seconds and check for any defect/fault
your product# show ethernet cfm errors
your product#
Shows no link failure, as no error is detected at any of the bridges.
SNMP Configurations
At Switch1
- Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:37}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 7}
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1]
% snmp0 get {fsMIEcfmMaFormat.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.1.1 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.1.1 {OCTET STRING} 6D:61:6F:70:37}
% snmp0 get {fsMIEcfmMaCcmInterval.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.1.1 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.1.1 INTEGER 2}
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-ID = 1]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.1.1.1}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.1.1.1 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.1.1.1}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.1.1.1 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.1.1.1}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.1.1.1 INTEGER down}
% snmp0 get {fsMIEcfmMepActive.0.1.1.1}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.1.1.1 INTEGER true}
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.1.1.1}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.1.1.1 INTEGER true}
At Switch2
- Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:37}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 7}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 4}
[Index: Interface Number = 2, MD-level = 7, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.2.7.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.2.7.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2]
% snmp0 get {fsMIEcfmMdFormat.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.2 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.2 {OCTET STRING} 4F:50:34}
% snmp0 get {fsMIEcfmMdMdLevel.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.2 INTEGER 4}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2]
% snmp0 get {fsMIEcfmMaFormat.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.2.2 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.2.2 {OCTET STRING} 6D:61:6F:70:34}
% snmp0 get {fsMIEcfmMaCcmInterval.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.2.2 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.2.2 INTEGER 4}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 3]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.2.2.3}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.2.2.3 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.2.2.3}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.2.2.3 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.2.2.3}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.2.2.3 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.2.2.3}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.2.2.3 INTEGER true}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 4}
[Index: ContextID = 0, MD-Index = 3]
% snmp0 get {fsMIEcfmMdFormat.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.3 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.3 {OCTET STRING} 4F:50:32}
% snmp0 get {fsMIEcfmMdMdLevel.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.3 INTEGER 2}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3]
% snmp0 get {fsMIEcfmMaFormat.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.3.3 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.3.3 {OCTET STRING} 6D:61:6F:70:32}
% snmp0 get {fsMIEcfmMaCcmInterval.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.3.3 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.3.3 INTEGER 4}
% snmp0 get {fsMIEcfmMaMhfCreation.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.5.0.3.3 INTEGER defMHFdefault}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.3.3.5 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.3.3.5 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.3.3.5 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.3.3.5 INTEGER true}
[Index: Interface Number = 3, MD-level = 2, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.3.2.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.3.2.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.3.3.5}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.3.3.5 INTEGER true}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 3]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.2.2.3}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.2.2.3 INTEGER true}
At Switch3
- Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:34}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 4}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 2}
[Index: Interface Number = 3, MD-level = 4, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.3.4.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.3.4.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2]
% snmp0 get {fsMIEcfmMdFormat.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.2 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.2 {OCTET STRING} 4F:50:32}
% snmp0 get {fsMIEcfmMdMdLevel.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.2 INTEGER 2}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2]
% snmp0 get {fsMIEcfmMaFormat.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.2.2 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.2.2 {OCTET STRING} 6D:61:6F:70:32}
% snmp0 get {fsMIEcfmMaCcmInterval.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.2.2 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.2.2 INTEGER 4}
% snmp0 get {fsMIEcfmMaMhfCreation.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.5.0.2.2 INTEGER defMHFdefault}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 6]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.2.2.6 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.2.2.6 INTEGER 3}
% snmp0 get {fsMIEcfmMepDirection.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.2.2.6 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.2.2.6 INTEGER true}
[Index: Interface Number = 2, MD-level = 2, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.2.2.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.2.2.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 6]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.2.2.6}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.2.2.6 INTEGER true}
At Switch5
- Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:37}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 7}
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1]
% snmp0 get {fsMIEcfmMaFormat.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.1.1 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.1.1 {OCTET STRING} 6D:61:6F:70:37}
% snmp0 get {fsMIEcfmMaCcmInterval.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.1.1 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.1.1}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.1.1 INTEGER 2}
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-ID = 2]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.1.1.2}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.1.1.2 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.1.1.2}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.1.1.2 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.1.1.2}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.1.1.2 INTEGER down}
% snmp0 get {fsMIEcfmMepActive.0.1.1.2}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.1.1.2 INTEGER true}
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.1.1.2}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.1.1.2 INTEGER true}
At Switch6
- Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:37}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 7}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 4}
[Index: Interface Number = 2, MD-level = 7, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.2.7.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.2.7.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2]
% snmp0 get {fsMIEcfmMdFormat.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.2 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.2 {OCTET STRING} 4F:50:34}
% snmp0 get {fsMIEcfmMdMdLevel.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.2 INTEGER 4}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2]
% snmp0 get {fsMIEcfmMaFormat.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.2.2 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.2.2 {OCTET STRING} 6D:61:6F:70:34}
% snmp0 get {fsMIEcfmMaCcmInterval.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.2.2 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.2.2 INTEGER 4}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 4]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.2.2.4}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.2.2.4 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.2.2.4}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.2.2.4 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.2.2.4}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.2.2.4 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.2.2.4}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.2.2.4 INTEGER true}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 4}
[Index: ContextID = 0, MD-Index = 3]
% snmp0 get {fsMIEcfmMdFormat.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.3 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.3 {OCTET STRING} 4F:50:32}
% snmp0 get {fsMIEcfmMdMdLevel.0.3}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.3 INTEGER 2}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3]
% snmp0 get {fsMIEcfmMaFormat.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.3.3 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.3.3 {OCTET STRING} 6D:61:6F:70:32}
% snmp0 get {fsMIEcfmMaCcmInterval.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.3.3 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.3.3 INTEGER 4}
% snmp0 get {fsMIEcfmMaMhfCreation.0.3.3}
{1.3.6.1.4.1.2076.160.1.0.5.1.5.0.3.3 INTEGER defMHFdefault}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.3.3.5 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.3.3.5 INTEGER 2}
% snmp0 get {fsMIEcfmMepDirection.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.3.3.5 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.3.3.5 INTEGER true}
[Index: Interface Number = 3, MD-level = 2, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.3.2.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.3.2.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.3.3.5}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.3.3.5 INTEGER true}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 4]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.2.2.4}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.2.2.4 INTEGER true}
At Switch7
- Display the details of all the MEPs and MIPs.
[Index: ContextID = 0, MD-Index = 1]
% snmp0 get {fsMIEcfmMdFormat.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.1 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.1 {OCTET STRING} 4F:50:34}
% snmp0 get {fsMIEcfmMdMdLevel.0.1}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.1 INTEGER 4}
[Index: ContextID = 0]
% snmp0 get {fsMIEcfmDefaultMdDefMhfCreation.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.5.0 INTEGER defMHFdefault}
% snmp0 get {fsMIEcfmDefaultMdDefLevel.0}
{1.3.6.1.4.1.2076.160.1.0.1.1.4.0 INTEGER 2}
[Index: Interface Number = 3, MD-level = 4, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.3.4.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.3.4.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2]
% snmp0 get {fsMIEcfmMdFormat.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.2.0.2 INTEGER charString}
% snmp0 get {fsMIEcfmMdName.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.3.0.2 {OCTET STRING} 4F:50:32}
% snmp0 get {fsMIEcfmMdMdLevel.0.2}
{1.3.6.1.4.1.2076.160.1.0.4.1.4.0.2 INTEGER 2}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2]
% snmp0 get {fsMIEcfmMaFormat.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.3.0.2.2 INTEGER charString}
% snmp0 get {fsMIEcfmMaName.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.4.0.2.2 {OCTET STRING} 6D:61:6F:70:32}
% snmp0 get {fsMIEcfmMaCcmInterval.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.7.0.2.2 INTEGER interval1s}
% snmp0 get {fsMIEcfmMaPrimaryVlanId.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.2.0.2.2 INTEGER 4}
% snmp0 get {fsMIEcfmMaMhfCreation.0.2.2}
{1.3.6.1.4.1.2076.160.1.0.5.1.5.0.2.2 INTEGER defMHFdefault}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 6]
% snmp0 get {fsMIEcfmMepPrimaryVid.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.4.0.2.2.6 Unsigned32 0}
% snmp0 get {fsMIEcfmMepIfIndex.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.2.0.2.2.6 INTEGER 3}
% snmp0 get {fsMIEcfmMepDirection.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.3.0.2.2.6 INTEGER up}
% snmp0 get {fsMIEcfmMepActive.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.5.0.2.2.6 INTEGER true}
[Index: Interface Number = 2, MD-level = 2, VlanID = 4]
% snmp0 get {fsMIEcfmMipRowStatus.2.2.4}
{1.3.6.1.4.1.2076.160.1.1.6.1.5.2.2.4 INTEGER active}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 6]
% snmp0 get {fsMIEcfmExtMepCciEnabled.0.2.2.6}
{1.3.6.1.4.1.29601.2.13.1.2.3.1.7.0.2.2.6 INTEGER true}
At Switch1, Switch2, Switch3, Switch5, Switch6, Switch7
- Wait for 15 seconds and check for any defect/fault
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-ID = 1]
% snmp0 get {fsMIEcfmMepDefects.0.1.1.1}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.1.1.1 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 3]
% snmp0 get {fsMIEcfmMepDefects.0.2.2.3}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.2.2.3 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmMepDefects.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.3.3.5 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 6]
% snmp0 get {fsMIEcfmMepDefects.0.2.2.6}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.2.2.6 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-ID = 2]
% snmp0 get {fsMIEcfmMepDefects.0.1.1.2}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.1.1.2 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 2, MA-Index = 2, MEP-ID = 4]
% snmp0 get {fsMIEcfmMepDefects.0.2.2.4}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.2.2.4 {OCTET STRING} 00}
[Index: ContextID = 0, MD-Index = 3, MA-Index = 3, MEP-ID = 5]
% snmp0 get {fsMIEcfmMepDefects.0.3.3.5}
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.3.3.5 {OCTET STRING} 00}
Shows no link failure, as no error is detected at any of the bridges.
© 2024 Cisco and/or its affiliates. All rights reserved.
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms
For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks
Was this article helpful?