Sequence for Removing MEP 10.3 Flow-Based Metering
  • 10 Jul 2024
  • 1 Minute to read
  • Contributors
  • PDF

Sequence for Removing MEP 10.3 Flow-Based Metering

  • PDF

Article summary

The following configuration sequence is required for removing MEF 10.3 flow-based metering.

Configuration

configure terminal
no mef-envelope 20
end

configure terminal
policy-map 10
no set meter
end

configure terminal
set meter-st disable meter-id 10
no meter 10
no policy-map 10
no class-map 10
end

configure terminal
policy-map 20
no set meter
end

configure terminal
set meter-st disable meter-id 20
no meter 20
no policy-map 20
no class-map 20
end

configure terminal
policy-map 30
no set meter
end

configure terminal
set meter-st disable meter-id 30
no meter 30
no policy-map 30
no class-map 30
end

configure terminal
policy-map 40
no set meter
end

configure terminal
set meter-st disable meter-id 40
no meter 40
no policy-map 40
no class-map 40
end

configure terminal
policy-map 50
no set meter
end

configure terminal
set meter-st disable meter-id 50
no meter 50
no policy-map 50
no class-map 50
end

configure terminal
policy-map 60
no set meter
end

configure terminal
set meter-st disable meter-id 60
no meter 60
no policy-map 60
no class-map 60
end

configure terminal
policy-map 70
no set meter
end

configure terminal
set meter-st disable meter-id 70
no meter 70
no policy-map 70
no class-map 70
end

configure terminal
policy-map 80
no set meter
end

configure terminal
set meter-st disable meter-id 80
no meter 80
no policy-map 80
no class-map 80
end

© 2024 Cisco and/or its affiliates. All rights reserved.
 
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks



Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.