In this article, you will find configuration guidelines that must be followed for Burst Size configuration in the Policer / Metering Entry configuration.
Refer to the following table for the given range or traffic rate to be used in CIR / EIR parameter in Policer / Metering Entry.
Maximal Rate (CIR/EIR) [bps] | Max Burst (CBS/EBS) [Bytes] |
---|---|
65,535,000.00 | 55,295.00 |
1,310,710,000.00 | 514,040.00 |
13,107,100,000.00 | 4,184,000.00 |
131,071,000,000.00 | 33,543,680.00 |
1,310,710,000,000.00 | 268,421,120.00 |
13,107,100,000,000.00 | 2,147,440,640.00 |
Note: The configurable range for the CBS and EBS sizes is 0 - 2147440640 bytes.
© 2024 Accedian Networks Inc. All rights reserved. Accedian®, Accedian Networks®, the Accedian logo™, Skylight™, Skylight Interceptor™ and per-packet intel™, are trademarks or registered trademarks of Accedian Networks Inc. To view a list of Accedian trademarks visit: http://accedian.com/legal/trademarks/.