In this article, you will find configuration guidelines that must be followed for Burst Size configuration in the Policer / Metering Entry configuration.

Refer to the following table for the given range or traffic rate to be used in CIR / EIR parameter in Policer / Metering Entry.

Maximal Rate (CIR/EIR) [bps]Max Burst (CBS/EBS) [Bytes]
65,535,000.0055,295.00
1,310,710,000.00514,040.00
13,107,100,000.004,184,000.00
131,071,000,000.0033,543,680.00
1,310,710,000,000.00268,421,120.00
13,107,100,000,000.002,147,440,640.00


Note: The configurable range for the CBS and EBS sizes is 0 - 2147440640 bytes.

© 2024 Accedian Networks Inc. All rights reserved. Accedian®, Accedian Networks®,  the Accedian logo™, Skylight™, Skylight Interceptor™ and per-packet intel™, are trademarks or registered trademarks of Accedian Networks Inc. To view a list of Accedian trademarks visit: http://accedian.com/legal/trademarks/. 