Platform Monitor Commands
  • 05 Jul 2023
  • 3 Minutes to read
  • Contributors
  • Dark
    Light
  • PDF

Platform Monitor Commands

  • Dark
    Light
  • PDF

Article Summary

This section presents a detailed description of the CLI commands used to configure and review the configuration of the Platform Monitor application.

Command ModeAccess MethodPromptExit method
Platform Monitor ConfigurationThe User EXEC mode command is used. This is the initial mode to start a session.your product(platform-monitor)#The logout method is used.

Platform Monitor CLI commands are categorized as follows:

  • Display Commands

Display Commands

This section includes Platform Monitor display commands.

show platform-monitor

Command Objective:
This command displays Platform information.

Syntax:
show platform-monitor { cpu | cpuload | memory | fs | psu | fan | temp}

Parameter Description:

  • cpu - CPU usage
  • cpuload - CPU load average
  • memory - Memory usage
  • fs - File System usage
  • psu - Power Supply
  • fan - Fan
  • temp - Temperature

Mode:
Privileged EXEC Mode

Example:

Your Product# show platform-monitor cpu
CPU used : 9%

show platform-monitor transceiver

Command Objective:
This command lists transceivers connected on Flex 100 ports and provides high-level information for the following:

  • Type
  • Vendor name
  • Part number
  • Serial number

Syntax:
show platform-monitor transceiver

Mode:
Privileged EXEC Mode

Example:

Your Product# show platform-monitor transceiver
--------------------------------------------------------------------------------
Port     Type                 Vendor           Part             Serial          
                              Name             Number           Number          
--------------------------------------------------------------------------------
1        100GBASE-CR4         FS               Q28-PC01         G2006502622-2   
2        100GBASE-SR4         Accedian         7QM-000          L2102090233     
3        100GBASE-LR4         Accedian         7QN-000          L2011190077     
4        100GBASE-ER4         Accedian         7QP-000          L2106250012     
AUX      100G SWDM4           Gigalight        7SM-400          M110803029

show platform-monitor transceiver [port]

Command Objective:
This command provides further information for each transceiver that is set port ID: 1 to 4 or AUX (as labeled on the product's front panel):

  • Temperature (C)
  • Supply Voltage (V)
  • Tx Bias Current (mA)
  • Tx Output Power (dBm)
  • Rx Optical Pwr (dBm)
  • Type
  • Vendor name
  • Part number
  • Serial number

Syntax:
show platform-monitor transceiver [port]

Parameter Description:

  • port - 1 to 4 or AUX (as labeled on the product's front panel)

Mode:
Privileged EXEC Mode

Example:

Your Product# show platform-monitor transceiver 2
Transceiver in 2
Identifier : QSFP28
Transceiver Type : 100GBASE-SR4
Connector Type : MPO 1x12
Wavelength : 850nm
Encoding : 64B/66B
Signaling Rate : 25500 MBd
Transfer Distance : 70m (OM3), 100m (OM4)
Vendor Name : Accedian
Vendor OUI : 00:24:FD
Vendor PN : 7QM-000
Vendor Rev : S1
Vendor SN : L2102090233
Date Code (yy-mm-dd) : 21-02-09
Diagnostic Support : Yes
SFP memory (Location : A0H)
===============================================================================
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
000: 11 DC 0C 80 00 00 00 40 20 02 00 05 FF 00 00 23 * .......@ ......# *
016: 00 00 32 00 41 63 63 65 64 69 61 6E 20 20 20 20 * ..2.Accedian *
032: 20 20 20 20 00 00 24 FD 37 51 4D 2D 30 30 30 20 * ..$.7QM-000 *
048: 20 20 20 20 20 20 20 20 53 31 42 68 07 D0 46 5A * S1Bh..FZ *
064: 02 00 30 9A 4C 32 31 30 32 30 39 30 32 33 33 20 * ..0.L2102090233 *
080: 20 20 20 20 32 31 30 32 30 39 20 20 0C 00 67 8F * 210209 ..g. *
096: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 * ................ *
112: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 * ................ *
===============================================================================
Transceiver Digital Diagnostic Monitoring (DDM)
===============================================================================
Value Low Alarm Low Warn High Warn High Alarm
-------------------------------------------------------------------------------
Temperature (C) 29.31 0.00 5.00 65.00 70.00
Supply Voltage (V) 3.30 2.90 3.00 3.50 3.60
===============================================================================
Transceiver Lane Digital Diagnostic Monitoring (DDM)
===============================================================================
Low Alarm Low Warn High Warn High Alarm
-------------------------------------------------------------------------------
Lane Tx Bias Current (mA) 2.00 3.00 13.00 14.00
Lane Tx Output Power (dBm) -9.40 -8.40 2.40 3.40
Lane Rx Optical Pwr (dBm) -11.00 -10.60 2.40 3.40
-------------------------------------------------------------------------------
Lane ID Tx Bias(mA) Tx Pwr(dBm) Rx Pwr(dBm)
-------------------------------------------------------------------------------
1 7.00 -0.18 -1.35
2 7.00 0.05 0.17
3 7.00 0.37 0.01
4 7.00 0.13 0.40
===============================================================================

© 2024 Accedian Networks Inc. All rights reserved. Accedian®, Accedian Networks®,  the Accedian logo™, Skylight™, Skylight Interceptor™ and per-packet intel™, are trademarks or registered trademarks of Accedian Networks Inc. To view a list of Accedian trademarks visit: http://accedian.com/legal/trademarks/. 


Was this article helpful?

What's Next
Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.