Enabling Ethernet CFM
  • 10 Jul 2024
  • 1 Minute to read
  • Contributors
  • PDF

Enabling Ethernet CFM

  • PDF

Article summary

When Skylight Flex switch is made up, by default ECFM, it is in the start state, but operationally in disable state. That is, it does not generate, receive, or reply to any of the CFM PDUs.

For Ethernet CFM entities to function, ECFM must be enabled, and all the ECFM entities must be configured (MD, MA, MEP, and MIP).

CLI Configurations

To enable ECFM

  1. Enter into the global configuration mode.
    your product# configure terminal
  2. Enable CFM processing globally.
    your product(config)# ethernet cfm enable
  3. Return to the privileged EXEC mode.
    your product(config)# exit

To disable ECFM

  1. Enter into the global configuration mode and disable CFM processing globally.
    your product(config)# no ethernet cfm enable

SNMP Configurations

To enable ECFM

  1. Enable CFM processing globally.[Index: ContextID = 0]
    % snmp0 set {{fsMIEcfmModuleStatus.0 enabled }}

  2. Disable CFM processing globally. [Index: ContextID = 0]
    % snmp0 set {{fsMIEcfmModuleStatus.0 disabled }}

© 2024 Cisco and/or its affiliates. All rights reserved.
 
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms

For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks



Was this article helpful?

Changing your password will log you out immediately. Use the new password to log back in.
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
Enter a valid email
Enter a valid password
Your profile has been successfully updated.