This article describes the checking of CCM errors on the bridges (CUST1 and CUST3)
CLI Configurations
At CUST1
- Display the logged CFM continuity check error conditions
your product# show ethernet cfm errors
MEP-ID : 10
Level VLAN RMEP-ID Current defect type
----- ---- ------- -------------------
5 2 30 mac status defect
Implies that CUST-3 is sending CCM with port-status as blocked.
At CUST3
- Display the logged CFM continuity check error conditions
your product# show ethernet cfm errors
MEP-ID : 30
Level VLAN RMEP-ID Current defect type
----- ---- ------- -------------------
5 2 10 remote defect indication
Implies that CUST-1 is sending CCM with RDI as enabled.
SNMP Configurations
At CUST1
- Display the logged CFM continuity check error conditions. [Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-ID = 10]
% snmp0 get {fsMIEcfmMepDefects.0.1.1.10 }
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.1.1.10 {OCTET STRING} 40}
Implies that CUST-3 is sending CCM with port-status as blocked.
At CUST3
- Display the logged CFM continuity check error conditions. [Index: ContextID = 0, MD-Index = 1, MA-Index = 1, MEP-ID = 30]
% snmp0 get {fsMIEcfmMepDefects.0.1.1.30**}**
{1.3.6.1.4.1.2076.160.1.0.7.1.14.0.1.1.30 {OCTET STRING} 80}
Implies that CUST-1 is sending CCM with RDI as enabled.