- Print
- PDF
Alarm Manager CLI commands are categorized as follows:
Alarms are notifications related to fault detection or any other irregularities.
Configuration Commands
This section includes alarm management configuration commands.
alarm-manager edit
Command Objective:
This command edits the configuration of the Alarm Manager.
Syntax:
set alarm-manager [{raise-time (1000-50000)}]
[{clear-time (1000-50000)}]
[{led {“enable” | “disable” }}]
[{syslog-output {“enable” | “disable”}}]
[{snmp-output {“enable” | “disable”}}]
Parameter Description:
- raise-time - The timeout value in milliseconds waited while passing from an Inactive Alarm status to an Active status; permitted range is between 1000 and 50000.
- clear-time - The timeout value in milliseconds waited while passing from an Active Alarm status to an Inactive status; permitted range is between 1000 and 50000.
- led - The LED used to refer alarms status
- syslog-output - Whether the alarms are logged in the syslog
- snmp-output - Whether MIB notifications are triggered for the alarm-manager
Mode:
Global Configuration mode
Example:
Your Product(config)# set alarm-manager raise-time 2500 clear-time 10000 led disable syslog-outp disable snmp-output enable
alarm < resource > edit
Command Objective:
This command edits the configuration of a specific or a group of alarms.
Syntax:
set alarm fan [<integer(1-4)>] [{equipment_not_present | stall_alarm | aging_alarm}] [{reporting { enable | disable }}] [{ severity{ critical | major | minor | warning }}] [{service-affecting { yes | no }}]
Note: This command is for Assurance Sensor F100 only.
set alarm fan [<integer(1-3)>] [{equipment_not_present | stall_alarm | aging_alarm}] [{reporting { enable | disable }}] [{ severity{ critical | major | minor | warning }}] [{service-affecting { yes | no }}]
Note: This command is for Assurance Sensor F25 only.
set alarm psu [<integer(1-2)>] [{equipment_not_present | high_voltage_alarm | low_voltage_alarm | temperature_fault | power_fault}] [{reporting { enable | disable }}] [{ severity{ critical | major | minor | warning }}] [{service-affecting { yes | no }}]
Note: This command is for Assurance Sensor F100 only.
set alarm psu [<integer(1)>] [{feed <integer(1-2)>}] [{equipment_not_present | high_voltage_alarm | low_voltage_alarm | temperature_fault | power_fault}] [{reporting { enable | disable }}] [{ severity{ critical | major | minor | warning }}] [{service-affecting { yes | no }}]
Note: This command is for Assurance Sensor F25 only.
set alarm fpga [{equipment_not_present | high_temp_alarm | low_temp_alarm | high_temp_warn | low_temp_warn}] [{reporting { enable | disable }}] [{ severity{ critical | major | minor | warning }}] [{service-affecting { yes | no }}]
set alarm asic [{equipment_not_present | high_temp_alarm | low_temp_alarm | high_temp_warn | low_temp_warn}] [{reporting { enable | disable }}] [{ severity{ critical | major | minor | warning }}] [{service-affecting { yes | no }}]
set alarm cpu [{equipment_not_present | high_temp_alarm | low_temp_alarm | high_temp_warn | low_temp_warn}] [{reporting { enable | disable }}] [{ severity{ critical | major | minor | warning }}] [{service-affecting { yes | no }}]
set alarm transceiver [id <integer(0-4)>] [lane <integer(0-3)>] [{equipment_not_present | high_voltage_alarm | low_voltage_alarm | high_temp_alarm | low_temp_alarm | high_temp_warn | low_temp_warn | high_voltage_warn | low_voltage_warn | high_tx_bias_current | low_tx_bias_current | high_tx_bias_cur_warn | low_tx_bias_cur_warn | high_tx_power_alarm | low_tx_power_alarm | high_tx_power_warn | low_tx_power_warn | high_rx_power_alarm | low_rx_power_alarm | high_rx_power_warn | low_rx_power_warn}] [{reporting { enable | disable }}] [{ severity{ critical | major | minor | warning}}] [{service-affecting { yes | no }}]
set alarm sync_module [equipment_not_present] [{reporting { enable | disable }}] [{ severity{ critical | major | minor | warning }}] [{service-affecting { yes | no }}]
set alarm interface [id <integer(1-8)>] [link_down] [{reporting { enable | disable }}] [{ severity{ critical | major | minor | warning }}] [{service-affecting { yes | no }}]
set alarm mep [interface id <integer(1-7)>] [vlan <integer(1-4094)>] [meg-level <integer(0-7)>] [mpid <integer(1-4000)>] [{ defxconnccm | deferrorccm | defremoteccm | defmacstatus | defrdiccm | dloc | dunl | dunpr | dmmg | dunm | dunp | drdi | dais | dlck | dcsf_los | dcsf_fdi | dcsf_rdi}] [{reporting { enable | disable }}] [{ severity{ critical | major | minor | warning }}] [{service-affecting { yes | no }}]
Parameter Description:
- no - Indication that the command is to be removed
- Alarm key
- reporting - The alarm reporting state
- severity - The alarm severity level
- service-affecting - If alarm is service affecting
Mode:
Global Configuration mode
Example:
Your Product(config)# set alarm fan 1 aging_alarm reporting enable severity minor service-affecting no
Display and Retrive Commands
This section includes alarm management commands for displaying and retrieving data.
alarm history export
Command Objective:
This command is for retrieving data history.
Syntax:
set alarm history export { <sftp_url> | <tftp_url> }
Parameter Description:
- < sftp_url > - The SFTP URL to export the history
Note: SFTP exporting must support usage of the port made by command ( configure terminal ; sftp port <integer (1025-65535)> ; end ). - < tftp_url > - The TFTP URL to export the history
Mode:
User EXEC Mode
Example:
Your Product(config)# set alarm history export sftp://user:password@mypc.com/alarm_history_db.gz
show alarm history
Command Objective:
This command displays the history of the alarm objects.
Note: Alarm history is restricted to displaying 2,000 entries in the CLI.
Syntax:
show alarm history
Mode:
User EXEC Mode
Example:
Your Product# show alarm history
Resource Resource Address Standing Condition Status S-A Date and time
-------- ---------------- ------------------ ------ --- -------------
Fan 0/Fan-tray[1] stall_alarm inactive no 2024-01-01 10:08:12 UTC
Fan 0/Fan-tray[2] stall_alarm active no 2024-01-01 10:08:12 UTC
Fan 0/Fan-tray[3] stall_alarm active no 2024-01-01 10:08:12 UTC
Fan 0/Fan-tray[4] stall_alarm active no 2024-01-01 09:08:12 UTC
Fan 0/Fan-tray[0] aging_alarm inactive no 2024-01-01 09:08:12 UTC
show alarm inventory
Command Objective:
This command displays the description of all the alarms supported by the system (with relative configurable elements); can be refined by Resource.
Syntax:
show alarm inventory
show alarm inventory fan [<integer(1-4)>]
Note: This command is for Assurance Sensor F100 only.
show alarm inventory fan [<integer(1-3)>]
Note: This command is for Assurance Sensor F25 only.
show alarm inventory psu [<integer(1-2)>]
show alarm inventory fpga
show alarm inventory asic
show alarm inventory cpu
show alarm inventory transceiver [id <integer(0-4)>]
show alarm inventory sync_module
show alarm inventory interface [id <integer(1-8)>]
show alarm inventory mep [interface id <integer(1-7)>] [vlan <integer(1-4094)>] [meg-level <integer(0-7)>] [mpid <integer(1-4000)>]
Parameter Description:
- Alarm key
Mode:
User EXEC Mode
Example:
Your Product# show alarm inventory
Resource Resource Address Standing Condition Reporting Status Severity S-A
-------- ---------------- ------------------ --------- ------ -------- ---
Fan 0/Fan-tray[0] equipment_not_present enabled active warning no
Fan 0/Fan-tray[0] stall_alarm disabled inactive minor no
PSU 0/PSU-Tray[0] equipment_not_present enabled active warning no
FPGA 0/HwCompFpga/TempSensor[0] low_temp_alarm enabled active minor no
ASIC 0/HwCompAsic/TempSensor[0] low_temp_alarm disabled active minor no
CPU 0/HwCompCpu/TempSensor[0] low_temp_alarm enabled active minor no
Transceiver 0/TransceiverSlot[1]/Lane[0] low_voltage_alarm disabled active minor no
SynchModule 0/SynchModule[0] equipment_not_present disabled active warning no
Interface 0/0/Interface[2] link_down enabled active major no
MEP 0/0/If[1]/Vlan[2]/MDL[1]/MEP[1] defxconnccm disabled active minor no
show alarm-manager
Command Objective:
This command displays the configuration of the Alarm Manager.
Syntax:
show alarm-manager
Mode:
User EXEC Mode
Example:
Your Product# show alarm-manager
raise-time : 2500 milliseconds
clear-time : 10000 miliseconds
led : enabled
syslog-output : enabled
SNMP-output : enabled
show alarm specific
Command Objective:
This command displays the configuration of a specific alarm.
Syntax:
show alarm fan <integer(1-4)> {equipment_not_present | stall_alarm | aging_alarm}
Note: This command is for Assurance Sensor F100 only.
show alarm fan <integer(1-3)> {equipment_not_present | stall_alarm | aging_alarm}
Note: This command is for Assurance Sensor F25 only.
show alarm psu <integer(1-2)> {equipment_not_present | high_voltage_alarm | low_voltage_alarm | temperature_fault | power_fault}
Note: This command is for Assurance Sensor F100 only.
show alarm psu (1) [{feed (1-2)}] {equipment_not_present | high_voltage_alarm | low_voltage_alarm | temperature_fault
| power_fault}
Note: This command is for Assurance Sensor F25 only.
show alarm fpga {equipment_not_present | high_temp_alarm | low_temp_alarm | high_temp_warning | low_temp_warning}
show alarm asic {equipment_not_present | high_temp_alarm | low_temp_alarm | high_temp_warning | low_temp_warning}
show alarm cpu {equipment_not_present | high_temp_alarm | low_temp_alarm | high_temp_warning | low_temp_warning}
show alarm transceiver id (1-5) [lane (0-3)] {equipment_not_present | high_voltage_alarm | low_voltage_alarm | high_temp_alarm | low_temp_alarm | high_temp_warn | low_temp_warn | high_voltage_warn | low_voltage_warn | high_tx_bias_current | low_tx_bias_current | high_tx_bias_cur_warn | low_tx_bias_cur_warn | high_tx_power_alarm | low_tx_power_alarm | high_tx_power_warn | low_tx_power_warn | high_rx_power_alarm | low_rx_power_alarm | high_rx_power_warn | low_rx_power_warn}
show alarm sync_module {equipment_not_present}
show alarm interface id <integer(1-8)> {link_down}
show alarm mep interface id <integer(1-7)> vlan <integer(1-4094)> meg-level <integer(0-7)> mpid <integer(1-4000)> { defxconnccm | deferrorccm | defremoteccm | defmacstatus | defrdiccm | dloc | dunl | dunpr | dmmg | dunm | dunp | drdi | dais | dlck | dcsf_los | dcsf_fdi | dcsf_rdi }
Parameter Description:
- Alarm key
Mode:
User EXEC Mode
Example:
Your Product# show alarm fan 2 stall
resource : Fan
resource address : 0/Fan-tray[2]
standing condition : stall_alarm
reporting : disabled
status : inactive
severity : minor
service-affecting : no
description : The FAN speed is below the manufacturer's recommended number of rpm.
last change : 2024-01-01 10:08:12
show alarm summary
Command Objective:
This command displays the list of raised Alarms; can be refined by resource.
Syntax:
show alarm summary
show alarm summary fan [<integer(1-4)>]
Note: This command is for Assurance Sensor F100 only.
show alarm summary fan [<integer(1-3)>]
Note: This command is for Assurance Sensor F25 only.
show alarm summary psu [<integer(1-2)>]
show alarm summary fpga
show alarm summary asic
show alarm summary cpu
show alarm summary transceiver [id <integer(1-5)>] [lane <integer(0-3)>]
show alarm summary sync_module
show alarm summary interface [id <integer(1-8)>]
show alarm summary mep [interface id <integer(1-7)>] [vlan <integer(1-4094)>] [meg-level <integer(0-7)>] [mpid <integer(1-4000)>]
Parameter Description:
- Alarm key
Mode:
User EXEC Mode
Example:
Your Product# show alarm summary
Resource Resource Address Standing Condition Severity S-A Last Change
-------- ---------------- ------------------ -------- --- -----------
Fan 0/Fan-tray[0] equipment_not_present warning no 2022-01-01 10:08:12 UTC
PSU 0/PSU-Tray[0] equipment_not_present warning no 2022-01-01 10:08:12 UTC
FPGA 0/HwCompFpga/TempSensor[0] low_temp_alarm minor no 2022-01-01 10:08:12 UTC
ASIC 0/HwCompAsic/TempSensor[0] low_temp_alarm minor no 2022-01-01 10:08:12 UTC
CPU 0/HwCompCpu/TempSensor[0] low_temp_alarm minor no 2022-01-01 10:08:12 UTC
Transceiver 0/TransceiverSlot[1]/Lane[0] low_voltage_alarm minor no 2022-01-01 10:08:12 UTC
SynchModule 0/SynchModule[0] equipment_not_present warning no 2022-01-01 10:08:12 UTC
Interface 0/0/Interface[2] link_down major no 2022-01-01 10:08:12 UTC
MEP 0/0/If[1]/Vlan[2]/MDL[1]/MEP[1] defxconnccm minor no 2022-01-01 10:08:12 UTC
© 2024 Cisco and/or its affiliates. All rights reserved.
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms
For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks