- Print
- PDF
You can view any alarm associated with the devices Skylight orchestrator manages.
Alarms are collected by the following:
- Permanent CLI sessions established with each managed device
- When this connection is established, Skylight orchestrator queries the managed device for its list of active alarms, and updates its internal alarm list. The same query is reissued whenever the device is resynchronized via the resynchronization process.
- SNMP messages Skylight orchestrator can:
- Collect events for alarms raised and cleared from managed device via SNMP.
The alarm list for each device is kept up-to-date at all times.
- Be configured to send notifications to northbound destinations such as OSS.
- Messages are set up by accessing Administration ▶ SNMP.
- Managed devices must be set up to send SNMP messages for alarms raised and cleared.
For detailed information about how to configure Skylight orchestrator for SNMP, see "Configuring Alarm Handling via SNMP".
Alarm Categories
Alarms are categorized by severity and color, as follows:
Severity | Color | Details |
---|---|---|
Warning | Provides status information. Note: Warning alarms related to loss of connectivity with devices are displayed as LOC alarms that can be filtered in the GUI. LOC: Skylight orchestrator has lost contact with a managed device. | |
Minor | An error condition has occurred that does not seriously affect system functionality. | |
Major | A serious degradation of service or hardware malfunction has occurred and requires immediate attention to restore system functionality. | |
Critical | A service-affecting condition has occurred and requires immediate corrective action. |
The severity of each alarm is displayed in the Severity column on the alarm page. In addition, the alarm banner at the bottom of the page displays the number of alarms per severity.
Alarm Dashboard
The alarm dashboard gives you a high-level statistical view of alarm events. The alarm dashboard is displayed on the bottom of the alarm page, and provides you with the following statistics:
Note: Text summaries have replaced pie charts as of Skylight orchestrator 23.12.
Type | Text Summary | Details |
---|---|---|
Severity | Displays the breakdown of alarm events by Severity, in percentages | |
Probable cause | Displays the breakdown of alarm events by Probable cause, in percentages. | |
Alarm type | Displays the breakdown of alarm events by Alarm type, in percentages. | |
Condition type | Displays the breakdown of alarm events by Condition type, in percentages. |
© 2024 Cisco and/or its affiliates. All rights reserved.
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms
For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks