Provider Connectivity Assurance
Support Portal
cisco.com
Login
Contents
x
Getting Started
Provider Connectivity Assurance
Legacy Orchestrator
Skylight Gateway
Assurance Sensor Agents
Assurance Sensor Capture
Assurance Sensor Control
Assurance Module Dock
Assurance Sensor Modules
Assurance Sensor SFP
Assurance Sensor GT-GT-S, LT-S, and LX-S
Assurance Sensor F100 and F25
Partner Enablement
Accedian Skylight Legacy Products and Documentation
Legal
Powered by
Configuring ECFM on Provider Bridges
14 Articles
in this category
Contributors
Share this
Print
Share
Contents
Configuring ECFM on Provider Bridges
14 Articles
in this category
Written by
Jonathan Poole
Share
Overview
The following articles describe the configuration of the ECFM functionality for provider bridges on the following sample topology. Configuration of ECFM on Provider bridges MAC Address of ports on the bridges is of form 00:0m:02:03:04:0n, w...
Written by
Jonathan Poole
Updated on : 27 Jun 2023
Configuring the Bridge Mode
This article describes the configuration of bridge mode for the bridges. CLI Configurations At Switch1 and Switch5 Set the bridge-mode as customer and spanning tree mode as mst. your product#configure terminal your product(config)# shut...
Written by
Jonathan Poole
Updated on : 27 Jun 2023
Configuring Interfaces on Switches
This article describes the configuration of interfaces on the bridges. CLI Configurations At Switch1, Switch2, Switch5 and Switch6 Create interfaces as up. your product(config)# interface gigabitethernet 0/2 your product(config-if)#...
Written by
Jonathan Poole
Updated on : 27 Jun 2023
Configuring VLAN on Switches
This article describes the configuration of VLAN on switches. CLI Configurations At Switch1 and Switch5 Create the VLAN 2. your product(config)# vlan 2 Make interfaces as member ports of this VLAN. your product(config-vlan)#...
Written by
Jonathan Poole
Updated on : 27 Jun 2023
Configuring Interface Types and VLAN Mapping
This article describes the configuration of interface types and mapping of VLAN. CLI Configurations At Switch2 Set the interface as CustomerEdgePort. your product(config)# interface gigabitethernet 0/2 your product(config-if)# bri...
Updated on : 27 Jun 2023
Initializing ECFM
This article describes the enabling of ECFM, MIP CCM database, and traceroute caching. CLI Configurations At Switch1, Switch2, Switch3, Switch4, Switch5, Switch6, Switch7, Switch8 Enable ECFM. your product(config) # ethernet cfm ena...
Updated on : 27 Jun 2023
Configuring Maintenance Domain, Service and MEPs
This article describes the configuration of MD, MA, and MEPs on the switches. CLI Configurations At Switch1 Configure the Maintenance Domain, Service and MEP List . your product(config)# ethernet cfm domain name OP7 level 7 you...
Updated on : 27 Jun 2023
Verifying the Configured MPs (MEP, MIP)
This article describes how to verify the configured MD, MA, and MEPs. CLI Configurations At Switch1 Display the details of all the MEPs and MIPs. your product# show ethernet cfm maintenance-point local --------------------------------...
Updated on : 27 Jun 2023
Shutdown Interface
This article describes the configuration of interface P2 to raise a defect/fault in sample topology. CLI Configurations At Switch5 Make interface P2 as down. your product(config)# interface gigabitethernet 0/2 your product(config-if)#...
Updated on : 27 Jun 2023
Checking for CCM Errors
This article describes the verification of generated CCM errors. CLI Configurations At Switch1 Display the logged CFM continuity check error conditions. your product# show ethernet cfm errors MEP-ID : 1 Level VLAN RMEP-ID Current d...
Updated on : 25 Jan 2022
Verifying and Isolating Fault
This article describes the initiation of loop back and link trace messages to verify and isolate a fault. CLI Configurations At Switch1 Initiate Traceroute to isolate any link failure (error/fault/defect). your product# traceroute eth...
Updated on : 27 Jun 2023
Bridge UP Interface
This article describes the configuration of the interface. CLI Configurations At Switch5 Make interface P2 as up your product(config)# interface gigabitethernet 0/2 your product(config-if)# no shutdown SNMP Configurations At Sw...
Updated on : 27 Jun 2023
Initializing Y.1731
This article describes how to enable Y.1731. CLI Configurations At Switch1, Switch2, Switch3, Switch5, Switch6, and Switch7 Enable the Y.1731 status. your product(config)# ethernet cfm y1731 enable SNMP Configurations At Switch...
Updated on : 25 Jan 2022
Checking Alarm Indication Signal and Locked Features
This article describes how to enable the Alarm Indication Signal ( AIS ) and Locked ( LCK ) features. CLI Configurations At Switch6 Verify CCM errors your product# show ethernet cfm errors Shows no link failure, as no error is det...
Written by
Jonathan Poole
Updated on : 27 Jun 2023
Change password!
Changing your password will log you out immediately. Use the new password to log back in.
Current password
Current password is required
New password
New password must be at least 8 characters long. It should contain at least one upper and lower case letter, number, and a special character.
Confirm password
Confirm password must be at least 8 characters long. It should contain at least one upper and lower case letter, number, and a special character.
Confirm password should be same as new password
Update
Change profile
Success!
First Name
First name must have atleast 2 characters. Numbers and special characters are not allowed.
Last Name
Last name must have atleast 1 characters. Numbers and special characters are not allowed.
New email
Enter a valid email
Re-enter your password
Enter a valid password
Your profile has been successfully updated.
Update
Logout