alarm edit
alarm edit - Edit alarm configuration
Description:
Alarm edit allows you to change the configuration of an alarm.
Syntax:
alarm edit <alarm-number> {{disable | enable} |
{service-affecting {yes | no}} |
{severity {minor | major | critical | informational}} |
{state {enable | disable}} |
{description <description-text>}}+
Parameters:
Parameter | Description |
---|---|
<alarm-number> | <decimal>.<decimal>.<decimal> |
<description-text> | <string> |
description | The alarm description. |
disable | Disable the alarm. If the alarm is triggered, nothing happens (see the note below). |
enable | Enable the alarm. If the alarm is triggered, it will be reported as defined (see the note below). |
service-affecting | Tag the alarm as service-affecting or not. |
severity | The severity level of the alarm when it is raised. |
state | Enable or disable the alarm. If the alarm is triggered when enabled, it will be reported as defined. Otherwise, nothing will happen. |
Note: Using "disable" or "enable" as stand-alone arguments, i.e. not preceded by "state", is deprecated. This syntax remains valid for backward compatibility, but the best practice is to always use "state enable" and "state disable".
alarm reporting
alarm reporting - Enable alarm status reporting
Description:
Enable alarm status reporting via different ways.
Syntax:
alarm reporting {{led {disable | enable}} |
{snmp {disable | enable}} |
{syslog {disable | enable}}}
Parameters:
Parameter | Description |
---|---|
led | Enable the LEDs on the front panel of the unit to report the alarms. |
snmp | Enable the reporting of alarms via SNMP traps. |
syslog | Enable the reporting of alarms via entries in the syslog. |
alarm show configuration
alarm show configuration - Show alarm configuration
Description:
Display the alarm reporting behavior.
Syntax:
alarm show configuration [<alarm-id>] [more]
Parameters:
Parameter | Description |
---|---|
<alarm_id> | <decimal>.<decimal>.<decimal>.<decimal> |
Output:
alarm show configuration
Codes: E - Enabled, SA - Service Affecting
Number E SA Severity Device name Description
---------------- - -- -------- -------------------------------- ----------------------------------------------------------
0.1.1.1 Y Y Major --- Link down on PORT-LOCAL-1
0.1.2.1 Y Y Major --- Link down on PORT-LOCAL-2
0.6.1.30 Y N Major --- Time-of-day synchronization - May affect delay measurements
0.6.1.10 Y N Major --- NTP client lost server communication
0.6.1.11 Y N Major --- NTP client used interface without timestamp capability
0.6.1.12 Y N Major --- Remote NTP server used an interface without timestamp capability
0.7.4.1 Y N Major --- VCAgent communication failure with Vision EMS
0.7.4.11 Y N Major --- VCAgent High Resolution Regulator statistics buffer full
0.7.4.3 Y N Minor --- VCAgent High Resolution Regulator instances validation
0.7.4.14 Y N Major --- VCAgent High Resolution SOAM DMM statistics buffer full
0.7.4.6 Y N Minor --- VCAgent High Resolution SOAM DMM instances validation
0.7.4.13 Y N Major --- VCAgent High Resolution SOAM PL statistics buffer full
0.7.4.5 Y N Minor --- VCAgent High Resolution SOAM PL instances validation
0.7.4.17 Y N Major --- VCAgent High Resolution SOAM SLM statistics buffer full
0.7.4.9 Y N Minor --- VCAgent High Resolution SOAM SLM instances validation
0.7.4.27 Y N Major --- VCAgent High Resolution FlowMETER statistics buffer full
0.7.4.26 Y N Minor --- VCAgent High Resolution FlowMETER instances validation
0.19.1.1 Y N Minor --- One or more certificates is about to expire
0.19.1.2 Y N Major --- One or more certificates has expired
1.10.1.1 Y N Major P130-3014 Loss of connectivity with P130-3014
1.10.1.2 Y N Major P130-3014 Device mismatch with P130-3014
1.10.1.3 Y Y Critical P130-3014 Device P130-3014 sent Dying Gasp
alarm show configuration 0.1.1.1
Alarm number: 0.1.1.1
State : Enabled
Severity : Major
Service affecting: Yes
Description : Link down on PORT-LOCAL-1
Device name : ---
alarm show reporting
alarm show reporting - Show alarm reporting configuration
Description:
Display the alarm reporting parameters.
Syntax:
alarm show reporting
alarm show status
alarm show status - Show alarms current status
Description:
Display alarm status based on specified parameters. If an alarm number is specified, the detailed status for this alarm is displayed. If no alarm number is specified, the status of all applicable alarms is displayed in a table format. By default, only the alarms that are enabled and active are displayed. If the option "all" is specified, the status will be displayed for all possible alarms.
Syntax:
alarm show status [<alarm_number> | active | all | more]
Parameters:
Parameter | Description |
---|---|
<alarm_number> | <decimal>.<decimal>.<decimal>.<decimal> |
Output:
alarm show status
Codes: E - Enabled, P - Present
Number E P Last Change Device name Description
----------------- - - ------------------------- -------------------------------- -----------------------------------------
0.6.1.10 Y Y 2025-03-26 10:20:02-04:00 --- NTP client lost server communication
3.1.2.1 Y Y 2025-03-26 10:46:19-04:00 P130-3095 Link down on PORT-P130-3095-UNI
4.1.2.1 Y Y 2025-03-26 10:46:50-04:00 P130-3084 Link down on PORT-P130-3084-UNI
5.1.2.1 Y Y 2025-03-26 10:47:20-04:00 P130-3015 Link down on PORT-P130-3015-UNI
6.1.2.1 Y Y 2025-03-26 10:47:50-04:00 P130-3086 Link down on PORT-P130-3086-UNI
alarm show status 0.6.1.10
Alarm number: 0.6.1.10
Enabled : Yes
Present : Yes
Severity : Major
Service affecting: No
Last change : 2025-03-26 10:20:02-04:00
Message :
Description : NTP client lost server communication
© 2025 Cisco and/or its affiliates. All rights reserved.
For more information about trademarks, please visit: Cisco trademarks
For more information about legal terms, please visit: Cisco legal terms
For legal information about Accedian Skylight products, please visit: Accedian legal terms and tradmarks