dry-contact-input

Prev Next

dry-contact-input edit

dry-contact-input edit - Change dry-contact configuration

Description:

With dry-contact-input edit, you can change the parameters of one of the available dry-contact input.

Syntax:

dry-contact-input edit <id> {
                    {state {enable|disable}} |
                    {normal-state {close|open}} |
                    {name <dry-contact-input-name>} |
                    {sampling-period <100-1000>} }+

Parameters:

Parameter Description
<id> <decimal>
state Enable/disable the use of the dry-contact input. When enabled, the alarm point for this input is created and the input is monitored according to the following monitoring configurations.
normal-state Selects the normal state of the input. An alarm is raised when the input state is different from the normal state for more than 3 consecutive samples. The input sampling rate is determined by the value of the input sampling period.
name Specifies the name of the dry-contact used in alarms.
sampling-period Determines the time, in milliseconds, between two consecutive readings of the input state. The values must be specified within the range of 100 and 1000 milliseconds in steps of 100 milliseconds.

dry-contact-input show configuration

dry-contact-input show configuration - Show dry-contact configuration

Description:

Display all configuration parameters of the available dry-contact input.

Syntax:

dry-contact-input show configuration

dry-contact-input show status

dry-contact-input show status - Show dry-contact status

Description:

Display status of the available dry-contact input.

Syntax:

dry-contact-input show status

© 2025 Cisco and/or its affiliates. All rights reserved.
 